Inlet Air 100 °F, 14.5 psia, Ø = 50% Outlet Air T = ?, 14.5 psia, Water Pool Ø = 100%, 800,000 ft/min T=T2 Qout R134a Condenser R-134a R-134a (to throttle/expander) (from compressor)
PLEASE DO NOT USE PSYCHROMETRIC CHART. THANK YOU
In the diagram below inlet air is drawn over a pool of liquid water in a steady-state, steady-flow isobaric process. Evaporation on the pool results
in saturated air at the exit. The pool of liquid water is assumed to be at the same temperature as the exit
air. Discharge fans at the exit provide a volumetric flow rate of 800,000 ft3/min.
Problem #2: Assume that the R134a chiller is turned off such that Qout = 0, but the evaporative cooler
system continues to operate. Determine:
a) The exit temperature, T2 (°F)
b) The mass flow rate dry air through the system (lbm/sec).
c) The rate of liquid water resupply required for continuous operation (lbm/hour).