Identify the mistakes in the pictures. Explain.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

Identify the mistakes in the pictures. Explain.

1. THE ELECTRICAL INSTALLATION SHOWN ON THE PLANS SHALL CONFORM
WITH THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, RULES
AND REGULATIONS OF THE LOCAL ELECTRIC COMPANY AND THE LOCAL
GOVERNMENT WHERE THE PROJECT WILL BE CONSTRUCTED.
2. ALL ELECTRICAL MATERIALS AND EQUIPMENT TO BE USED IN THIS
PROJECT SHALL BE BRAND-NEW AND OF APPROVED QUALITY AND BRAND.
3. THE ELECTRIC WIRINGS INSIDE THE BUILDING SHALL BE THROUGH PVC
CONDUIT PIPES NOT SMALLER THAN 20mm DIAMETER, SCHEDULE 40.
4. THERE SHALL BE ONLY ONE SERVICE DROP FROM THE NEAREST
ELECTRIC COMPANY POLE TO THE PROPOSED BUILDING.
5. WIRES TO BE USED INSIDE THE BUILDING SHALL NOT BE SMALLER THAN
3.5sq.mm. WITH 600V INSULATION.
6. THE TYPE OF POWER SERVICE TO BE SUPPLIED SHALL BE SINGLE PHASE,
220V, A.C.
7. MOUNTING HEIGHT OF ELECTRICAL DEVICES SHALL BE AS FOLLOWS:
a. WALL SWITCHES ----
b. CONVENIENCE OUTLETS-----.30 METER ABOVE FLOOR LINE
--1.37 METERS ABOVE FLOOR LINE
c. AIRCONDITIONING OUTLET--2.00 METERS ABOVE FLOOR LINE
d. PANEL BOARD---
e. KILOWATT-HOUR METER---1.85 METERS FROM GROUND TO CENTER
--1.37 METERS ABOVE FLOOR LINE
OF METER
f. WASHING MACHINE OUTLET- 1.5 METERS FROM FLOOR LINE
E GENERAL NOTES/ SPECIFICATION
2
Transcribed Image Text:1. THE ELECTRICAL INSTALLATION SHOWN ON THE PLANS SHALL CONFORM WITH THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, RULES AND REGULATIONS OF THE LOCAL ELECTRIC COMPANY AND THE LOCAL GOVERNMENT WHERE THE PROJECT WILL BE CONSTRUCTED. 2. ALL ELECTRICAL MATERIALS AND EQUIPMENT TO BE USED IN THIS PROJECT SHALL BE BRAND-NEW AND OF APPROVED QUALITY AND BRAND. 3. THE ELECTRIC WIRINGS INSIDE THE BUILDING SHALL BE THROUGH PVC CONDUIT PIPES NOT SMALLER THAN 20mm DIAMETER, SCHEDULE 40. 4. THERE SHALL BE ONLY ONE SERVICE DROP FROM THE NEAREST ELECTRIC COMPANY POLE TO THE PROPOSED BUILDING. 5. WIRES TO BE USED INSIDE THE BUILDING SHALL NOT BE SMALLER THAN 3.5sq.mm. WITH 600V INSULATION. 6. THE TYPE OF POWER SERVICE TO BE SUPPLIED SHALL BE SINGLE PHASE, 220V, A.C. 7. MOUNTING HEIGHT OF ELECTRICAL DEVICES SHALL BE AS FOLLOWS: a. WALL SWITCHES ---- b. CONVENIENCE OUTLETS-----.30 METER ABOVE FLOOR LINE --1.37 METERS ABOVE FLOOR LINE c. AIRCONDITIONING OUTLET--2.00 METERS ABOVE FLOOR LINE d. PANEL BOARD--- e. KILOWATT-HOUR METER---1.85 METERS FROM GROUND TO CENTER --1.37 METERS ABOVE FLOOR LINE OF METER f. WASHING MACHINE OUTLET- 1.5 METERS FROM FLOOR LINE E GENERAL NOTES/ SPECIFICATION 2
TUBULAR OR COMPACT FLOURESSCENT LIGHT
PINLIGHT WITH COMPACT FLOURESCENT BULB
DUPLEX CONVENIENCE OUTLET
WP O WEATHER PROOF DUPLEX CcONVENIENCE OUTLET
REFO REFRIGERATOR OUTLET
Re THREE-PRONGS COOKING RANGE OUTLET
ACUO AIRCONDITIONING OUTLET
CIRCUIT HOMERUN FOR LIGHTING
(NUMBERS INSIDE CIRCLES IDENTIFY THE CIRCUITS)
CIRCUIT HOMERUN FOR APPLIANCE OUTLETS
S3w THREE-WAY SWITCH
WHO WATER HEATER OUTLET
WMO WASHING MACHINE WITH DRYER OUTLET
LPP I LIGHTING AND POWER PANELBOARD
Q TV ANTENNA OUTLET
MATVE MASTER ANTENNA TV OUTLET/ CABINET
TTC E TELEPHONE TERMINAL CABINET
TELEPHONE OUTLET
V TELEPHONE EXTENSION/ INTERCOMMUNICATION
E LEGEND/ ELECTRICAL SYMBOLS
1
Transcribed Image Text:TUBULAR OR COMPACT FLOURESSCENT LIGHT PINLIGHT WITH COMPACT FLOURESCENT BULB DUPLEX CONVENIENCE OUTLET WP O WEATHER PROOF DUPLEX CcONVENIENCE OUTLET REFO REFRIGERATOR OUTLET Re THREE-PRONGS COOKING RANGE OUTLET ACUO AIRCONDITIONING OUTLET CIRCUIT HOMERUN FOR LIGHTING (NUMBERS INSIDE CIRCLES IDENTIFY THE CIRCUITS) CIRCUIT HOMERUN FOR APPLIANCE OUTLETS S3w THREE-WAY SWITCH WHO WATER HEATER OUTLET WMO WASHING MACHINE WITH DRYER OUTLET LPP I LIGHTING AND POWER PANELBOARD Q TV ANTENNA OUTLET MATVE MASTER ANTENNA TV OUTLET/ CABINET TTC E TELEPHONE TERMINAL CABINET TELEPHONE OUTLET V TELEPHONE EXTENSION/ INTERCOMMUNICATION E LEGEND/ ELECTRICAL SYMBOLS 1
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Analog to digital converters
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,