Groundwater at a rate of 1,500 gpm, containing three volatile organic compounds (VOCs), is to be stripped in a trayed tower with air to produce drinking water that will meet EPA standards. Rele- vant data are given below. Determine the minimum air flow rate in scfm (60°F, 1 atm) and the number of equilibrium stages required if an air flow rate of twice the minimum is used and the tower operates at 25°C and 1 atm. Determine the composition in parts per million (ppm) for each VOC in the resulting drinking water. Component 1,2-Dichloroethane (DCA) Trichloroethylene (TCE) K-value 60 650 1,1,1-Trichloroethane (TCA) 275 Note: ppm = parts per million by weight. Concentration, ppm Ground- water 85 120 145 Max. for Drinking water 0.005 0.005 0.200

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question

3

Groundwater at a rate of 1,500 gpm, containing three volatile
organic compounds (VOCs), is to be stripped in a trayed tower with
air to produce drinking water that will meet EPA standards. Rele-
vant data are given below. Determine the minimum air flow rate in
scfm (60°F, 1 atm) and the number of equilibrium stages required if
an air flow rate of twice the minimum is used and the tower operates
at 25°C and 1 atm. Determine the composition in parts per million
(ppm) for each VOC in the resulting drinking water.
Component
K-value
1,2-Dichloroethane (DCA)
60
Trichloroethylene (TCE)
650
1,1,1-Trichloroethane (TCA)
275
Note: ppm = parts per million by weight.
Concentration, ppm
Ground-
water
85
120
145
Max. for
Drinking
water
0.005
0.005
0.200
Transcribed Image Text:Groundwater at a rate of 1,500 gpm, containing three volatile organic compounds (VOCs), is to be stripped in a trayed tower with air to produce drinking water that will meet EPA standards. Rele- vant data are given below. Determine the minimum air flow rate in scfm (60°F, 1 atm) and the number of equilibrium stages required if an air flow rate of twice the minimum is used and the tower operates at 25°C and 1 atm. Determine the composition in parts per million (ppm) for each VOC in the resulting drinking water. Component K-value 1,2-Dichloroethane (DCA) 60 Trichloroethylene (TCE) 650 1,1,1-Trichloroethane (TCA) 275 Note: ppm = parts per million by weight. Concentration, ppm Ground- water 85 120 145 Max. for Drinking water 0.005 0.005 0.200
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps

Blurred answer
Similar questions
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The