Given the below single line diagram where, the red curve is for a PD1 circuit breaker (Upstream). The blue curve is for a PD2 circuit breaker (Down stream) SUPPLY See the following curves to check the discrimination at the red, green and blue arrows (if the fault happened at the downstream PD2) |NOT DISCRIMINATING WITH UPSTREAM DEVICE 4h 2h 1h 30 m 20 m 10 m 3 m 2 m 50 s la1536 A 0.800 s 0.500 s 0.300 s 0.200 s 0.080 s 0.050 s 0.030s 0.020 s 0.010s 0.0050 s 0.0010s Current (A) The time selectivity between PD1 and PD2 if the fault happens at PD2 for a current rating coincides with green arrow is 000'001 000'01 000'1 Tripping Time

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Discrimination (Selectivity or coordination) Problem:
Given the below single line diagram where, the red curve is for a PD1 circuit breaker (Upstream). The blue curve is for a PD2 circuit breaker
(Down stream)
SUPPLY
See the following curves to check the discrimination at the red, green and blue arrows (if the fault happened at the downstream PD2)
N NOT DISCRIMINATING WITH UPSTREAM DEVICE
4h
2h
1h
30 m
10 m
50 s
8s
5s
25
0,800 s
0.500 s
0.300 s
200s
0.080 s
0.050s
8838:
0.010s
0.0050 s
0.0010s
Current (A)
The time selectivity between PD1 and PD2 if the fault happens at PD2 for a current rating coincides with green arrow is
Select one:
O a
At = 47seconds
1/20/22, 4:08 PM
O b. At = 27seconds
Oc.
At = 57seconds
Od. At = 37seconds
O e. None of these
Of At = 7seconds
Tripping Time
Transcribed Image Text:Discrimination (Selectivity or coordination) Problem: Given the below single line diagram where, the red curve is for a PD1 circuit breaker (Upstream). The blue curve is for a PD2 circuit breaker (Down stream) SUPPLY See the following curves to check the discrimination at the red, green and blue arrows (if the fault happened at the downstream PD2) N NOT DISCRIMINATING WITH UPSTREAM DEVICE 4h 2h 1h 30 m 10 m 50 s 8s 5s 25 0,800 s 0.500 s 0.300 s 200s 0.080 s 0.050s 8838: 0.010s 0.0050 s 0.0010s Current (A) The time selectivity between PD1 and PD2 if the fault happens at PD2 for a current rating coincides with green arrow is Select one: O a At = 47seconds 1/20/22, 4:08 PM O b. At = 27seconds Oc. At = 57seconds Od. At = 37seconds O e. None of these Of At = 7seconds Tripping Time
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Analysis of Single Phase and Three Phase System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,