Given is a complex energy system shown in figure below. Infinite bus Transmission line SG Synch. Gen PG lin Quot Plant että että tä Ind. IM1 motor Ind. motor IM2 Synchr. SM motor la Transformer: 3-phase, 500kVA, 14,400/480 V, 60 Hz, R=0.01 pu, X=0.085pu Transmission line: ZL = 1.5+j 10 Q Synchronous Generator (SG): A 480-V, 100-kW, two-pole, three-phase, 60-Hz synchronous generator's prime mover has a no-load speed of 3630 r/min and a full-load speed of 3570 r/min. Synchronous Motor (SM): A 480-V, 100-kW, 60-Hz, six-pole, Y-connected synchronous motor has a synchronous reactance of 1.5 22 and a negligible armature resistance. The rotational losses are 5kW. Assume that the flux in the motor varies linearly with the field current. For motor operating at 0.85 PF lag., the field current is 10.0 A. Induction Motor 1 (IM1): A 480-V, 60-Hz, two-pole Y-connected induction motor has rated slip of 0.04. The equivalent circuit parameters are R₁-0.079, R₂=0.0650, X₁-0.340, X₂=0.170, XM-7.20, Prot-2.25kW Induction Motor 2 (IM2): A 480-V, 200kW, 60-Hz, two-pole, 0.80 PF lagging Y-connected induction motor has rated efficiency of 95.24%.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
Answer this question based on the attached image. For IM1, calculate the line current, stator power factor and the input power?
Given is a complex energy system shown in figure below.
Infinite bus
Transmission line
SG
Synch.
Gen
A
HI
sotto
LG
in
lin
S
PICK
liat 92
Plant
Ind.
motor
Ind.
motor
IM1
IM2
Synchr. SM
motor
Transformer: 3-phase, 500kVA, 14,400/480 V, 60 Hz, R=0.01 pu, X=0.085pu
Transmission line: Z₁ = 1.5+j 10 Q
Synchronous Generator (SG):
A 480-V, 100-kW, two-pole, three-phase, 60-Hz synchronous generator's prime
mover has a no-load speed of 3630 r/min and a full-load speed of 3570 r/min.
Synchronous Motor (SM):
A 480-V, 100-kW, 60-Hz, six-pole, Y-connected synchronous motor has a
synchronous reactance of 1.5 22 and a negligible armature resistance. The
rotational losses are 5kW. Assume that the flux in the motor varies linearly with
the field current. For motor operating at 0.85 PF lag., the field current is 10.0 A.
Induction Motor 1 (IM1):
A 480-V, 60-Hz, two-pole Y-connected induction motor has rated slip of 0.04. The
equivalent circuit parameters are
R₁=0.079, R₂=0.0650, X₁=0.34Q, X₂=0.17Q, XM-7.20, Prot-2.25kW
Induction Motor 2 (IM2):
A 480-V, 200kW, 60-Hz, two-pole, 0.80 PF lagging Y-connected induction motor
has rated efficiency of 95.24%.
Transcribed Image Text:Given is a complex energy system shown in figure below. Infinite bus Transmission line SG Synch. Gen A HI sotto LG in lin S PICK liat 92 Plant Ind. motor Ind. motor IM1 IM2 Synchr. SM motor Transformer: 3-phase, 500kVA, 14,400/480 V, 60 Hz, R=0.01 pu, X=0.085pu Transmission line: Z₁ = 1.5+j 10 Q Synchronous Generator (SG): A 480-V, 100-kW, two-pole, three-phase, 60-Hz synchronous generator's prime mover has a no-load speed of 3630 r/min and a full-load speed of 3570 r/min. Synchronous Motor (SM): A 480-V, 100-kW, 60-Hz, six-pole, Y-connected synchronous motor has a synchronous reactance of 1.5 22 and a negligible armature resistance. The rotational losses are 5kW. Assume that the flux in the motor varies linearly with the field current. For motor operating at 0.85 PF lag., the field current is 10.0 A. Induction Motor 1 (IM1): A 480-V, 60-Hz, two-pole Y-connected induction motor has rated slip of 0.04. The equivalent circuit parameters are R₁=0.079, R₂=0.0650, X₁=0.34Q, X₂=0.17Q, XM-7.20, Prot-2.25kW Induction Motor 2 (IM2): A 480-V, 200kW, 60-Hz, two-pole, 0.80 PF lagging Y-connected induction motor has rated efficiency of 95.24%.
Expert Solution
steps

Step by step

Solved in 4 steps with 8 images

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,