Four variables, temperature ( T), humidity (H), time of day (D), and day of week (W) are regulated by the air conditioning system, as defined as follows: 0-if temp is greater than 78°F T 0- otherwise 1- if humidity is greater than 85% H 0 - otherwise 1- if time is between 8AM to 5PM 0 - otherwise 1- if it is Monday to Friday 0 - otherwise |The unit is to be turned on by logic under the following circumstances: - Temp exceeds 78°F and time of the day is between 8AM to 5PM · The humidity exceeds 85%, the temp exceeds 78°F and it is a weekend - The humidity is greater than 85%, temp is greater than 78°F and the time is between 8AM to 5PM It is Saturday or Sunday and humidity exceeds 85%

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

Required:
A. Truth Table
B. Simplified Logic Equation using Boolean Algebra based on the Condition C. Simplified Logic Equation using K-Mapping based on the Truth Table
D. Simplified Circuit

Four variables, temperature ( T), humidity (H), time of day (D), and day of week (W) are
regulated by the air conditioning system, as defined as follows:
0-if temp is greater than 78°F
T
0- otherwise
1- if humidity is greater than 85%
H
0 - otherwise
1- if time is between 8AM to 5PM
0 - otherwise
1- if it is Monday to Friday
0 - otherwise
|The unit is to be turned on by logic under the following circumstances:
- Temp exceeds 78°F and time of the day is between 8AM to 5PM
· The humidity exceeds 85%, the temp exceeds 78°F and it is a weekend
- The humidity is greater than 85%, temp is greater than 78°F and the time is between 8AM
to 5PM
It is Saturday or Sunday and humidity exceeds 85%
Transcribed Image Text:Four variables, temperature ( T), humidity (H), time of day (D), and day of week (W) are regulated by the air conditioning system, as defined as follows: 0-if temp is greater than 78°F T 0- otherwise 1- if humidity is greater than 85% H 0 - otherwise 1- if time is between 8AM to 5PM 0 - otherwise 1- if it is Monday to Friday 0 - otherwise |The unit is to be turned on by logic under the following circumstances: - Temp exceeds 78°F and time of the day is between 8AM to 5PM · The humidity exceeds 85%, the temp exceeds 78°F and it is a weekend - The humidity is greater than 85%, temp is greater than 78°F and the time is between 8AM to 5PM It is Saturday or Sunday and humidity exceeds 85%
Expert Solution
steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,