For the following statements show True or Fouls: 1- The continuous controllers are built using digital electronics such as resistor and capacitor. 2- The advantages of analog controllers are easier to implement complicated algorithms. X 3- Quantizing process is the process of converting a signal in analog form to digital form.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
For the following statements show True or Fouls:
1- The continuous controllers are built using digital electronics such as resistor and
capacitor.
2- The advantages of analog controllers are easier to implement complicated
algorithms. X
3- Quantizing process is the process of converting a signal in analog form to digital
form.
4- The holding device converts the sampled signal (in discrete time) into a
continuous signal.
5- The sampler may be considered as demodulator.
6- The train of unit impulse function is 6(t-kT).
7- The Z-transform of the function u(t) is Z(Z-1).
8- The digital control system is stable if all poles of the T.F lie inside of the
circle in Z-plane.
9- The Inverse Z-transform are three methods (Partial Fraction, Inversion by Long
Division and Inversion by Contour Integration).
10- In the Z-plane the magnitude of Z varies between (-1) and (1).
Transcribed Image Text:For the following statements show True or Fouls: 1- The continuous controllers are built using digital electronics such as resistor and capacitor. 2- The advantages of analog controllers are easier to implement complicated algorithms. X 3- Quantizing process is the process of converting a signal in analog form to digital form. 4- The holding device converts the sampled signal (in discrete time) into a continuous signal. 5- The sampler may be considered as demodulator. 6- The train of unit impulse function is 6(t-kT). 7- The Z-transform of the function u(t) is Z(Z-1). 8- The digital control system is stable if all poles of the T.F lie inside of the circle in Z-plane. 9- The Inverse Z-transform are three methods (Partial Fraction, Inversion by Long Division and Inversion by Contour Integration). 10- In the Z-plane the magnitude of Z varies between (-1) and (1).
Expert Solution
steps

Step by step

Solved in 4 steps with 1 images

Blurred answer
Knowledge Booster
Proportional, Integral, Derivative Controllers and their Combinations
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,