(Figure 1) shows a mass spectrometer, an analytical instrument used to identify the various molecules in a sample by measuring their charge-to-mass ratio q/m. The sample is ionized, the positive ions are accelerated (starting from rest) through a potential difference AV, and they then enter a region of uniform magnetic field. The field bends the ions into circular trajectories, but after just half a circle they either strike the wall or pass through a small opening to a detector. As the accelerating voltage is slowly increased, different ions reach the detector and are measured. Consider a mass spectrometer with a 200.00 mT magnetic field and an 8.0000 cm spacing between the entrance and exit holes.
(Figure 1) shows a mass spectrometer, an analytical instrument used to identify the various molecules in a sample by measuring their charge-to-mass ratio q/m. The sample is ionized, the positive ions are accelerated (starting from rest) through a potential difference AV, and they then enter a region of uniform magnetic field. The field bends the ions into circular trajectories, but after just half a circle they either strike the wall or pass through a small opening to a detector. As the accelerating voltage is slowly increased, different ions reach the detector and are measured. Consider a mass spectrometer with a 200.00 mT magnetic field and an 8.0000 cm spacing between the entrance and exit holes.
Related questions
Question
Answers that are incorrect are 96.537, 19.307, 193.07, 110.1, 48.260, 96.4, & 2413.0. Im not sure what I’m doing wrong, but any help is appreciated. Please solve part a of this problem that is attached below. Thank you!
![(Figure 1) shows a mass spectrometer, an analytical instrument used to identify
the various molecules in a sample by measuring their charge-to-mass ratio
q/m. The sample is ionized, the positive ions are accelerated (starting from
rest) through a potential difference AV, and they then enter a region of uniform
magnetic field. The field bends the ions into circular trajectories, but after just
half a circle they either strike the wall or pass through a small opening to a
detector. As the accelerating voltage is slowly increased, different ions reach
the detector and are measured. Consider a mass spectrometer with a
200.00 mT magnetic field and an 8.0000 cm spacing between the entrance
and exit holes.
Figure
1 of 1
AV
Detector](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F310bba8b-0c1b-4059-930b-e7b70b4ab3f7%2F1ace55be-0e6f-4ade-a573-69c4f194df10%2F0gzgtor_processed.jpeg&w=3840&q=75)
Transcribed Image Text:(Figure 1) shows a mass spectrometer, an analytical instrument used to identify
the various molecules in a sample by measuring their charge-to-mass ratio
q/m. The sample is ionized, the positive ions are accelerated (starting from
rest) through a potential difference AV, and they then enter a region of uniform
magnetic field. The field bends the ions into circular trajectories, but after just
half a circle they either strike the wall or pass through a small opening to a
detector. As the accelerating voltage is slowly increased, different ions reach
the detector and are measured. Consider a mass spectrometer with a
200.00 mT magnetic field and an 8.0000 cm spacing between the entrance
and exit holes.
Figure
1 of 1
AV
Detector
![E Readim
12 of 12
I Review | Constants
Part A
To five significant figures, what accelerating potential difference AV is required to detect the ion O ? The masses of the atoms are shown in the table; the mass of the missing electron is
less than 0.001 u and is not relevant at this level of precision. Use the following constants: 1 u = 1.6605 × 10-27 kg, e = 1.6022 × 10–19 C.
Atomic masses
12C
12.000 u
14N
14.003 u
160
15.995 u
Express your answer to five significant figures and include the appropriate units.
• View Available Hint(s)
HA
AVo: =
Value
V
Submit
Previous Answers
X Incorrect; Try Again; 12 attempts remaining
Part B
What accelerating potential difference AV is required to detect N,?
Express your answer to five significant figures and include the appropriate units.
• View Available Hint(s)](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F310bba8b-0c1b-4059-930b-e7b70b4ab3f7%2F1ace55be-0e6f-4ade-a573-69c4f194df10%2Fsblvk1l_processed.jpeg&w=3840&q=75)
Transcribed Image Text:E Readim
12 of 12
I Review | Constants
Part A
To five significant figures, what accelerating potential difference AV is required to detect the ion O ? The masses of the atoms are shown in the table; the mass of the missing electron is
less than 0.001 u and is not relevant at this level of precision. Use the following constants: 1 u = 1.6605 × 10-27 kg, e = 1.6022 × 10–19 C.
Atomic masses
12C
12.000 u
14N
14.003 u
160
15.995 u
Express your answer to five significant figures and include the appropriate units.
• View Available Hint(s)
HA
AVo: =
Value
V
Submit
Previous Answers
X Incorrect; Try Again; 12 attempts remaining
Part B
What accelerating potential difference AV is required to detect N,?
Express your answer to five significant figures and include the appropriate units.
• View Available Hint(s)
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)