EXAMPLE 2.15 Assume that a 5-kW air conditioner would run 80% of the time (80% duty cycle) during the peak hour and might be limited by utility remote control to a duty cycle of 65%. Determine the following: (a) The number of minutes of operation denied at the end of I h of control of the unit. (b) The amount of reduced energy consumption during the peak hour if such control is applied simultaneously to 100,000 air conditioners throughout the system. (c) The total amount of reduced energy consumption during the peak. (d) The total amount of additional reduction in energy consumption in part (c) if T&D losses at peak is 8%.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

EXAMPLE 2.15
Assume that a 5-kW air conditioner would run 80% of the time (80% duty cycle) during the peak hour
and might be limited by utility remote control to a duty cycle of 65%. Determine the following:
(a) The number of minutes of operation denied at the end of I h of control of the unit.
(b) The amount of reduced energy consumption during the peak hour if such control is applied
simultaneously to 100,000 air conditioners throughout the system.
(c) The total amount of reduced energy consumption during the peak.
(d) The total amount of additional reduction in energy consumption in part (c) if T&D losses
at peak is 8%.
Solution
(a) The amount of operation that is denied is
(0.80 - 0.65) x (60 min/h) = 9 min.
(b) The amount of reduced energy consumption during the peak is
(0.80 - 0.65) x (5 kW) = 0.75 kW
(c) The total amount of energy reduction for 100,000 units is
LlS(t) = Savg x [Duncont(t) - Dcont(t)] x N
= (5 kW) 3[0.80 - 0.65] x 100,000
=75 MW.
(d) The total additional amount of energy reduction due to the reduction in the T&D losses is
(75 MW) x 0.08 = 6 MW
Thus, the overall total reduction is
75MW+6MW=81 MW.
This example shows attractiveness of controlling air conditioners to utility company.

 

 

 

Q) Repeat Example 2.15, assuming that the 30-min monthly maximum demands of customers
A and Bare 27 and 42 kW, respectively. The new monthly energy consumptions by customers
A and Bare 8000 and 9000 kWh, respectively. The new lagging load PFs of A and Bare
0.90 and 0.70, respectively.

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Electric heating unit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,