Ex.5: A 10 MVA transformer operate at 25% overload, feeds 11 kV busbar through circuit breakers. The 11 Kv busbars feed two outgoing feeders through other breakers. 11 kv 8 US BARR TO MVA TRANS. 飞 525/1 352/1 The CTs housed in transformer and feeder circuit breaker have ratios of 525/1 and 352/1 respectively and all sets of C.T.S feed induction type over current relays having the following characteristics for a 100% plug setting. Plug setting multiplier P.S.M seconds 3.6 5 time 10 6 3.9 2.8 2.2 2.1 10 15 20 Time in for a multiplier of 1 The relays on feeder CB have plug setting of 100% for overload and 0% on earth fault, the time multiplier setting being 0.3 in all cases. a fault occurs on one of the outgoing feeders and the fault current flows into it via transformer. Find the operating time of transformer relay if the fault is 3 phase short circuit with a fault current magnitude of 5250 A in each phase.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
I need the answer as soon as possible
Ex.5: A 10 MVA transformer operate at 25% overload, feeds
11 kV busbar through circuit breakers. The 11 Kv busbars
feed two outgoing feeders through other breakers.
11kv BUS BAR
1O MV
TRANS.
一 母
525/1
352/1
The CTs housed in transformer and feeder circuit breaker
have ratios of 525/1 and 352/1 respectively and all sets of C.T.S
feed induction type over current relays having the following
characteristics for a 100% plug setting.
Plug setting multiplier P.S.M
Time in seconds
for
10 15 20
time 10 6 3.9 2.8 2.2 2.1
2
3.6 5
a
multiplier of 1
The relays on feeder CB have plug setting of 100% for
overload and 0% on earth fault, the time multiplier setting
being 0.3 in all cases . a fault occurs on one of the outgoing
feeders and the fault current flows into it via transformer.
Find the operating time of transformer relay if the fault is 3
phase short circuit with a fault current magnitude of 5250 A in
each phase.
Transcribed Image Text:Ex.5: A 10 MVA transformer operate at 25% overload, feeds 11 kV busbar through circuit breakers. The 11 Kv busbars feed two outgoing feeders through other breakers. 11kv BUS BAR 1O MV TRANS. 一 母 525/1 352/1 The CTs housed in transformer and feeder circuit breaker have ratios of 525/1 and 352/1 respectively and all sets of C.T.S feed induction type over current relays having the following characteristics for a 100% plug setting. Plug setting multiplier P.S.M Time in seconds for 10 15 20 time 10 6 3.9 2.8 2.2 2.1 2 3.6 5 a multiplier of 1 The relays on feeder CB have plug setting of 100% for overload and 0% on earth fault, the time multiplier setting being 0.3 in all cases . a fault occurs on one of the outgoing feeders and the fault current flows into it via transformer. Find the operating time of transformer relay if the fault is 3 phase short circuit with a fault current magnitude of 5250 A in each phase.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Coulomb's law
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,