Data: A microcomputer working with an 8085 processor operating at a frequency of 1MHZ, used to control a system in a potato production plant: 1. Thermal sensor connected to the RST 6.5 interrupt in case the oil temperature is higher than the safety limit The sensor works by outputting a digital signal at the high level (a pressure enhancer connected to the RST 7.5 interrupt in case the vapor pressure is above the safety limit gives high level signal 3. A temperature sensor that gives digital readings consisting of (8bit) 4. The main heating system operates by a digital signal line at a high level

Computer Networking: A Top-Down Approach (7th Edition)
7th Edition
ISBN:9780133594140
Author:James Kurose, Keith Ross
Publisher:James Kurose, Keith Ross
Chapter1: Computer Networks And The Internet
Section: Chapter Questions
Problem R1RQ: What is the difference between a host and an end system? List several different types of end...
icon
Related questions
Question
Please solve Quickly
Data: Amicrocomputer working with an 8085 processor operating at a frequency of 1MHZ, used to control a system in a potato production plant:
1. Thermal sensor connected to the RST 6.5 interrupt in case the oil temperature is higher than the safety limit The
sensor works by outputting a digital signal at the high level (a
pressure enhancer connected to the RST 7.5 interrupt in case the vapor pressure is above the safety limit gives
high level signal
3. A temperature sensor that gives digital readings consisting of
(8bit) 4. The main heating system operates by a digital signal line at a high level
H1 5. A pure heating system operates with a digital signal line at a high level
H2 6. A cooling system operates with a digital signal line at a high
level C1 7. Steam pressure leakage safety valve with digital signal SV1 (1=close and 0=open)
Required
1) Designing and linking the hardware components with the
microcomputer 2) The RST7.5 interrupt service sub-program works to open the safety valve SV1 at the disposed level
3) The RST6.5 interrupt service sub-program works to turn off the heating systems and operate the cooling system 4) A main
program code that works on Reading the digital temperature every 1 second, and keeping it folded within the following
limits (190-200) degrees Celsius (if the temperature is 20 degrees lower than this range, the additional heating
system will be operated, and if it is 20 degrees lower than this range, the cooling system will be operated) 5)
Digital signal lights to indicate the operation or non-operation of the systems and the safety valve
Transcribed Image Text:Data: Amicrocomputer working with an 8085 processor operating at a frequency of 1MHZ, used to control a system in a potato production plant: 1. Thermal sensor connected to the RST 6.5 interrupt in case the oil temperature is higher than the safety limit The sensor works by outputting a digital signal at the high level (a pressure enhancer connected to the RST 7.5 interrupt in case the vapor pressure is above the safety limit gives high level signal 3. A temperature sensor that gives digital readings consisting of (8bit) 4. The main heating system operates by a digital signal line at a high level H1 5. A pure heating system operates with a digital signal line at a high level H2 6. A cooling system operates with a digital signal line at a high level C1 7. Steam pressure leakage safety valve with digital signal SV1 (1=close and 0=open) Required 1) Designing and linking the hardware components with the microcomputer 2) The RST7.5 interrupt service sub-program works to open the safety valve SV1 at the disposed level 3) The RST6.5 interrupt service sub-program works to turn off the heating systems and operate the cooling system 4) A main program code that works on Reading the digital temperature every 1 second, and keeping it folded within the following limits (190-200) degrees Celsius (if the temperature is 20 degrees lower than this range, the additional heating system will be operated, and if it is 20 degrees lower than this range, the cooling system will be operated) 5) Digital signal lights to indicate the operation or non-operation of the systems and the safety valve
Expert Solution
steps

Step by step

Solved in 2 steps with 3 images

Blurred answer
Recommended textbooks for you
Computer Networking: A Top-Down Approach (7th Edi…
Computer Networking: A Top-Down Approach (7th Edi…
Computer Engineering
ISBN:
9780133594140
Author:
James Kurose, Keith Ross
Publisher:
PEARSON
Computer Organization and Design MIPS Edition, Fi…
Computer Organization and Design MIPS Edition, Fi…
Computer Engineering
ISBN:
9780124077263
Author:
David A. Patterson, John L. Hennessy
Publisher:
Elsevier Science
Network+ Guide to Networks (MindTap Course List)
Network+ Guide to Networks (MindTap Course List)
Computer Engineering
ISBN:
9781337569330
Author:
Jill West, Tamara Dean, Jean Andrews
Publisher:
Cengage Learning
Concepts of Database Management
Concepts of Database Management
Computer Engineering
ISBN:
9781337093422
Author:
Joy L. Starks, Philip J. Pratt, Mary Z. Last
Publisher:
Cengage Learning
Prelude to Programming
Prelude to Programming
Computer Engineering
ISBN:
9780133750423
Author:
VENIT, Stewart
Publisher:
Pearson Education
Sc Business Data Communications and Networking, T…
Sc Business Data Communications and Networking, T…
Computer Engineering
ISBN:
9781119368830
Author:
FITZGERALD
Publisher:
WILEY