Construct the logic circuit and truth table of the following scenario. A nuclear power station has a safety system based on three inputs to a logic circuit (network). A warning signal (S = 1) is produced when certain conditions in the nuclear power station occur based on these three inputs. Inputs Description of plant status T P W Binary Values 1 0 1 0 1 0 Temperature > 115°C Temperature ≤ 115°C Reactor Pressure > 15 bar Reactor Pressure ≤ 15 bar Cooling water > 120 liter/hour Cooling water≤ 120 liter/hour A warning signal (S = 1) will be produced when any of the following occurs: • either (a) Temperature >115°C and Cooling water <120 liters/hour • or (b) Temperature ≤115°C and Reactor pressure >15 bar or Cooling water ≤120 liters/hour

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Construct the logic circuit and truth table of the following scenario.
A nuclear power station has a safety system based on three inputs to a logic circuit
(network). A warning signal (S = 1) is produced when certain conditions in the nuclear
power station occur based on these three inputs.
Inputs
Description of plant status
T
P
W
Binary
Values
1
0
1
0
1
0
Temperature > 115°C
Temperature ≤ 115°C
Reactor Pressure > 15 bar
Reactor Pressure ≤ 15 bar
Cooling water > 120 liter/hour
Cooling water≤ 120 liter/hour
A warning signal (S = 1) will be produced when any of the following occurs:
• either (a) Temperature >115°C and Cooling water <120 liters/hour
• or (b) Temperature ≤115°C and Reactor pressure >15 bar or Cooling water ≤120
liters/hour
Transcribed Image Text:Construct the logic circuit and truth table of the following scenario. A nuclear power station has a safety system based on three inputs to a logic circuit (network). A warning signal (S = 1) is produced when certain conditions in the nuclear power station occur based on these three inputs. Inputs Description of plant status T P W Binary Values 1 0 1 0 1 0 Temperature > 115°C Temperature ≤ 115°C Reactor Pressure > 15 bar Reactor Pressure ≤ 15 bar Cooling water > 120 liter/hour Cooling water≤ 120 liter/hour A warning signal (S = 1) will be produced when any of the following occurs: • either (a) Temperature >115°C and Cooling water <120 liters/hour • or (b) Temperature ≤115°C and Reactor pressure >15 bar or Cooling water ≤120 liters/hour
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Logic Gate and Its Application
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,