Consider the given truss and connection detail for member CF as shown. Member CF is made of ASTM A992 steel (Fy - 350 MPa; Fu- 450 MPa), rolled as L125 x 125 x 10 shape. The connection is made of three 25-mm diameter bolts, arranged in one row at the centroidal line. The load P applied on the truss nodes is composed of both dead and live loads. Using LRFD specifications, determine the maximum permissible service live load LL (assume 1.2DL + 1.6LL loạc combination governs) (in kN) that can be applied on the truss such that the design of member CF is adequate. Assume all other members and gusset plates are adequately designed. The ratio of service live load to service dead load is 3.0. All truss dimensions are in mm.
Consider the given truss and connection detail for member CF as shown. Member CF is made of ASTM A992 steel (Fy - 350 MPa; Fu- 450 MPa), rolled as L125 x 125 x 10 shape. The connection is made of three 25-mm diameter bolts, arranged in one row at the centroidal line. The load P applied on the truss nodes is composed of both dead and live loads. Using LRFD specifications, determine the maximum permissible service live load LL (assume 1.2DL + 1.6LL loạc combination governs) (in kN) that can be applied on the truss such that the design of member CF is adequate. Assume all other members and gusset plates are adequately designed. The ratio of service live load to service dead load is 3.0. All truss dimensions are in mm.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
Related questions
Question
help me on this i will give upvote :)

Transcribed Image Text:Consider the given truss and connection detail for member CF as shown. Member CF is made of ASTM A992
steel (Fy = 350 MPa; Fu- 450 MPa), rolled as L125 x 125 x 10 shape. The connection is made of three 25-mm
diameter bolts, arranged in one row at the centroidal line. The load P applied on the truss nodes is composed of
both dead and live loads.
Using LRFD specifications, determine the maximum permissible service live load LL (assume 1.2DL+ 1.6LL load
combination governs) (in kN) that can be applied on the truss such that the design of member CF is adequate.
Assume all other members and gusset plates are adequately designed. The ratio of service live load to service
dead load is 3.0.
All truss dimensions are in mm.
3600
36.870
7200
36.870
3600
66.038
46.366
36.870

Transcribed Image Text:36.070
3600
66.030
48.366
36,870
D.
4800
9600
4800
50
50 + 50
Pcf
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps

Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you


Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON

Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning


Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON

Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning

Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education


Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning