Emissions How many Ibm of SO2 are emitted in the stack gas per Ibm of coal burned? i x 10-3 lbm SO2/lbm coal Hint Save for Later Percent Removal Attempts: 0 of 3 used Submit Answer What percentage of SO 2 produced in the furnace is removed in the scrubber? % Hint Save for Later Attempts: 0 of 3 used Submit Answer Coal containing 4.00 wt% S is burned at a rate of 1250.0 lbm/min in a boiler furnace. All of the sulfur in the coal is oxidized to SO2. The product gas is sent to a scrubber in which most of the SO2 is removed, and the scrubbed gas with the remaining SO2 then passes out of a stack to the atmosphere. An Environmental Protection Agency regulation requires that the gas in the stack must contain no more than 0.0180 lbm SO2/lbm of coal burned. To test compliance with this regulation a flowmeter and an SO2 analyzer are mounted in the stack. The volumetric flow rate of the scrubbed gas is found to be 2867 ft³/s and the SO2 analyzer reading is 45.0. Calibration data for the analyzer are given in the table below. Concentration of SO2 SO2 Analyzer Calibration Data C (g SO2/m³ gas) Reading (0-100 scale) 0.3 10.0 0.85 28.0 2.67 48.0 7.31 65.0 18.2 81.0 30.0 90.0 What is the concentration of SO2 in the outlet stack gas? i x 10-5 lbm/ft³ SUPPORT

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
Help with the following question, please read carefully and answer.
Emissions
How many Ibm of SO2 are emitted in the stack gas per Ibm of coal burned?
i
x 10-3 lbm SO2/lbm coal
Hint
Save for Later
Percent Removal
Attempts: 0 of 3 used
Submit Answer
What percentage of SO 2 produced in the furnace is removed in the scrubber?
%
Hint
Save for Later
Attempts: 0 of 3 used
Submit Answer
Transcribed Image Text:Emissions How many Ibm of SO2 are emitted in the stack gas per Ibm of coal burned? i x 10-3 lbm SO2/lbm coal Hint Save for Later Percent Removal Attempts: 0 of 3 used Submit Answer What percentage of SO 2 produced in the furnace is removed in the scrubber? % Hint Save for Later Attempts: 0 of 3 used Submit Answer
Coal containing 4.00 wt% S is burned at a rate of 1250.0 lbm/min in a boiler furnace.
All of the sulfur in the coal is oxidized to SO2.
The product gas is sent to a scrubber in which most of the SO2 is removed, and the scrubbed gas with the
remaining SO2 then passes out of a stack to the atmosphere.
An Environmental Protection Agency regulation requires that the gas in the stack must contain no more than
0.0180 lbm SO2/lbm of coal burned.
To test compliance with this regulation a flowmeter and an SO2 analyzer are mounted in the stack.
The volumetric flow rate of the scrubbed gas is found to be 2867 ft³/s and the SO2 analyzer reading is 45.0.
Calibration data for the analyzer are given in the table below.
Concentration of SO2
SO2 Analyzer Calibration Data
C (g SO2/m³ gas) Reading (0-100 scale)
0.3
10.0
0.85
28.0
2.67
48.0
7.31
65.0
18.2
81.0
30.0
90.0
What is the concentration of SO2 in the outlet stack gas?
i
x 10-5 lbm/ft³
SUPPORT
Transcribed Image Text:Coal containing 4.00 wt% S is burned at a rate of 1250.0 lbm/min in a boiler furnace. All of the sulfur in the coal is oxidized to SO2. The product gas is sent to a scrubber in which most of the SO2 is removed, and the scrubbed gas with the remaining SO2 then passes out of a stack to the atmosphere. An Environmental Protection Agency regulation requires that the gas in the stack must contain no more than 0.0180 lbm SO2/lbm of coal burned. To test compliance with this regulation a flowmeter and an SO2 analyzer are mounted in the stack. The volumetric flow rate of the scrubbed gas is found to be 2867 ft³/s and the SO2 analyzer reading is 45.0. Calibration data for the analyzer are given in the table below. Concentration of SO2 SO2 Analyzer Calibration Data C (g SO2/m³ gas) Reading (0-100 scale) 0.3 10.0 0.85 28.0 2.67 48.0 7.31 65.0 18.2 81.0 30.0 90.0 What is the concentration of SO2 in the outlet stack gas? i x 10-5 lbm/ft³ SUPPORT
Expert Solution
steps

Step by step

Solved in 2 steps with 7 images

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The