As an engineer responsible for monitoring works in the area of ​​mechanical systems, you must evaluate the following situation: a large client in the retail area has a refrigeration system where it stores some chilled or frozen products to be sold on the sales floor.
Recently, the customer's maintenance department has been questioning the system's performance and requested an evaluation of the system's behavior. You went to the location and requested some information from the maintenance manager about the system, who provided the following data:
 
- The system operates with R-134a refrigerant;
- The refrigerated environment is maintained at 0°C and the external environment at 26°C;
- The refrigerant flow rate in the system is 0.08 kg/s;
 
In addition to the data provided, you carried out some tests and measured the temperature of the refrigerant fluid at some specific points in the system, such as the compressor inlet and condenser outlet, finding values ​​of 0°C and 26°C respectively.


Source: Author, 2024

For simplification purposes, you modeled the system as an ideal cycle, neglecting some effects of pressure loss on the components.
 
Given this information, determine the following parameters for the system:

1 – What is the coefficient of performance (COP) of the refrigeration system?
 
Note: remember that 1 TR = 3.517 kW
 
Knowing that the system was initially designed to meet a thermal load of 5.0 TR, do you assess that the system is operating properly? Is the system undersized or oversized? Justify your answer.
Do it in a typeable way, in Word or virtual calculation, the handwriting hinders understanding.

CALOR
REJEITADO
CONDENSADOR
DISPOSITIVO
DE EXPANSÃO
EVAPORADOR
2
We
COMPRESSOR
CALOR
ABSORVIDO
Transcribed Image Text:CALOR REJEITADO CONDENSADOR DISPOSITIVO DE EXPANSÃO EVAPORADOR 2 We COMPRESSOR CALOR ABSORVIDO
Expert Solution
steps

Step by step

Solved in 2 steps with 4 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY