(c). What is the dynamic range of the method? Hint: it is NOT the entire concentration range. (d). A sample of water yielded an absorbance of 0.36. What is the concentration of As in the water?

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question

Solve (c) and (d)

A graphite furnace atomic absorption spectrophotometer (AAS) was used to determine the
arsenic (As) concentrations in drinking water. A large set of blank samples yielded an average
blank signal of 0.015 and a blank standard deviation of 0.0050. The following data were
obtained for a calibration curve.
[As] (ppm)
2.0
4.0
6.0
8.0
10.0
Absorbance
0.15
0.27
0.46
0.55
0.71
Using a spreadsheet on an Excel, create a graph of the data using symbols only for the data
points. Plot the line on the same graph and include the graph to this question. Answer the
following questions.
(a). What is the sensitivity of the method?
(b). Calculate the LOD and LOQ for As.
(c). What is the dynamic range of the method? Hint: it is NOT the entire
concentration range.
(d). A sample of water yielded an absorbance of 0.36. What is the concentration of
As in the water?
Transcribed Image Text:A graphite furnace atomic absorption spectrophotometer (AAS) was used to determine the arsenic (As) concentrations in drinking water. A large set of blank samples yielded an average blank signal of 0.015 and a blank standard deviation of 0.0050. The following data were obtained for a calibration curve. [As] (ppm) 2.0 4.0 6.0 8.0 10.0 Absorbance 0.15 0.27 0.46 0.55 0.71 Using a spreadsheet on an Excel, create a graph of the data using symbols only for the data points. Plot the line on the same graph and include the graph to this question. Answer the following questions. (a). What is the sensitivity of the method? (b). Calculate the LOD and LOQ for As. (c). What is the dynamic range of the method? Hint: it is NOT the entire concentration range. (d). A sample of water yielded an absorbance of 0.36. What is the concentration of As in the water?
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Quality Assurance and Calibration Methods
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY