B. Open-Ended Question 6. A 45 hp, 50 Hz, 415 V delta connected induction motor has a full load efficiency of 0.80 and p.f0.60. The p.f is to be improved to 0.9 using static capacitors. Determine (i) rating of capacitor bank kVAR, (ii) capacitance of each unit, if they connected as (a) delta, and (b) star, in μF.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
B. Open-Ended Question
6. A 45 hp, 50 Hz, 415 V delta connected induction motor has a full load efficiency of
0.80 and p.f0.60. The p.f is to be improved to 0.9 using static capacitors. Determine
(i) rating of capacitor bank kVAR,
(ii) capacitance of each unit, if they connected as (a) delta, and (b) star, in uF.
7. Figure 1 shows the electrical power system with rated capacity of S₁= S₂=25 MVA,
connected with two step-up transformers 11 kV/66 kV, respectively. The short
circuit fault at point 'p' occurs at the outlet of transmission line. Calculate the short
circuit current and three phase short circuit capacity occur at the point 'p'.
S₂=25 MVA
G₁
% Xg1 = 30
T₁
% XT1= 5
Transmission
line
11/66 kVA
S₂=25 MVA
T₂
CB
~) G₂ % Xg2 = 30
% XT2 = 8
11/66 kVA
Transcribed Image Text:B. Open-Ended Question 6. A 45 hp, 50 Hz, 415 V delta connected induction motor has a full load efficiency of 0.80 and p.f0.60. The p.f is to be improved to 0.9 using static capacitors. Determine (i) rating of capacitor bank kVAR, (ii) capacitance of each unit, if they connected as (a) delta, and (b) star, in uF. 7. Figure 1 shows the electrical power system with rated capacity of S₁= S₂=25 MVA, connected with two step-up transformers 11 kV/66 kV, respectively. The short circuit fault at point 'p' occurs at the outlet of transmission line. Calculate the short circuit current and three phase short circuit capacity occur at the point 'p'. S₂=25 MVA G₁ % Xg1 = 30 T₁ % XT1= 5 Transmission line 11/66 kVA S₂=25 MVA T₂ CB ~) G₂ % Xg2 = 30 % XT2 = 8 11/66 kVA
Expert Solution
steps

Step by step

Solved in 5 steps with 3 images

Blurred answer
Knowledge Booster
Stability Analysis in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,