(b) A synchronous generator connected with an equivalent cireuit of Figure Q4 is shown as below. Here, the armature resistance is being ignored. The field current is adjusted so that the terminal voltage is 480 V at no load. Develop and sketch the output phase voltage vs. load current characteristics of the generator under these condition as below: - i) 0.8 p.f. lagging load for 10 A, 30 A and 60 A load current ii) 0.8 p.f. leading load for 10 A, 30 A and 60 A load current Based on the characteristics as above, explain the changes of output phase voltage from the generator. Suggest the method to overcome of the instability of output phase voltage as shown? RA IA 0.2 2 j1.0 2 RĘ VF LF Figure Q4: Synchronous generator equivalent circuit

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
(b)
A synchronous generator connected with an equivalent circuit of Figure Q4 is shown as
below. Here, the armature resistance is being ignored. The field current is adjusted so
that the terminal voltage is 480 V at no load. Develop and sketch the output phase voltage
vs. load current characteristics of the generator under these condition as below: -
i) 0.8 p.f. lagging load for 10 A, 30 A and 60 A load current
ii) 0.8 p.f. leading load for 10 A, 30 A and 60 A load current
Based on the characteristies as above, explain the changes of output phase voltage from
the generator. Suggest the method to overcome of the instability of output phase voltage
as shown?
RA
IA
0.2 2 j1.0 2
RF
VF
LF
Figure Q4: Synchronous generator equivalent circuit
Transcribed Image Text:(b) A synchronous generator connected with an equivalent circuit of Figure Q4 is shown as below. Here, the armature resistance is being ignored. The field current is adjusted so that the terminal voltage is 480 V at no load. Develop and sketch the output phase voltage vs. load current characteristics of the generator under these condition as below: - i) 0.8 p.f. lagging load for 10 A, 30 A and 60 A load current ii) 0.8 p.f. leading load for 10 A, 30 A and 60 A load current Based on the characteristies as above, explain the changes of output phase voltage from the generator. Suggest the method to overcome of the instability of output phase voltage as shown? RA IA 0.2 2 j1.0 2 RF VF LF Figure Q4: Synchronous generator equivalent circuit
Expert Solution
steps

Step by step

Solved in 6 steps with 3 images

Blurred answer
Knowledge Booster
Stability Analysis in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,