ANSWER AS BEST AS YOU CAN FOR A THUMBS UP A sole owner (without employees) of a contracting firm was performing maintenance and repair work for a cork processing company.                                                            He was working on the motor for a Nu Vac 480-volt, 14.9-kilowatt pneumatic roof-mounted conveyor system. He found the motor to be running roughly. As he was examining it, the motor tripped the electric starter.                                                        He went to the electrical room on the third floor of the building to open the Square D 60-ampere, standard-duty disconnect switch rated at 600 volts. An explosion and electrical fault occurred, involving not only the switch but also a portion of the surrounding electric equipment.                                                           The ensuing electric arc burned the contractor. He was hospitalized with first- and second-degree burns to his right hand and arm and his face.                                                         The company processed cork, including grinding, sifting, and blending cork. Because of inadequate housekeeping, combustible cork dust was present throughout the electrical room. The open-type electric equipment was unsuitable for use in Class II, Division 1 or 2 locations.                                                                          What procedures AND policies could have been put in place to prevent this injury?

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

ANSWER AS BEST AS YOU CAN FOR A THUMBS UP

A sole owner (without employees) of a contracting firm was performing maintenance and repair work for a cork processing company.                                                           

He was working on the motor for a Nu Vac 480-volt, 14.9-kilowatt pneumatic roof-mounted conveyor system. He found the motor to be running roughly. As he was examining it, the motor tripped the electric starter.                                                       

He went to the electrical room on the third floor of the building to open the Square D 60-ampere, standard-duty disconnect switch rated at 600 volts. An explosion and electrical fault occurred, involving not only the switch but also a portion of the surrounding electric equipment.                                                          

The ensuing electric arc burned the contractor. He was hospitalized with first- and second-degree burns to his right hand and arm and his face.                                                        

The company processed cork, including grinding, sifting, and blending cork. Because of inadequate housekeeping, combustible cork dust was present throughout the electrical room. The open-type electric equipment was unsuitable for use in Class II, Division 1 or 2 locations. 

                                                                       

What procedures AND policies could have been put in place to prevent this injury? 

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Gear motor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,