Analyze three phase power system as shown in figure subject to three phase symmetrical fault occurred at bus 2 and compare voltages at different buses to analyze effects of faults on neighboring buses. Analyze contribution of adjacent buses in terms of fault currents and Compare currents flowing in the lines connecting different buses of three phase power system. Pre fault voltage at each bus is Vr = 1+ 0j = 1 < 0°. Pre fault currents are assumed to be zero. %3D j2 j3 (1) j1 [j1 j1 j1 = 1.67 Zpus j1 j2.55 j1.67

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question

Please solve it correctly and step by step . detailed and well explained answer is required. Thank you

Note: It is expected from student to analyze three phase symmetrical fault in three
phase power system.
Analyze three phase power system as shown in figure subject to three phase symmetrical fault
occurred at bus 2 and compare voltages at different buses to analyze effects of faults on neighboring
buses. Analyze contribution of adjacent buses in terms of fault currents and Compare currents
flowing in the lines connecting different buses of three phase power system. Pre fault voltage at each
bus is Vr = 1 + 0j = 1 < 0°. Pre fault currents are assumed to be zero.
j4
j2
j3
j1
Zbus = j1 j2.55 j1.67
lji j1.67
j1
j3
Transcribed Image Text:Note: It is expected from student to analyze three phase symmetrical fault in three phase power system. Analyze three phase power system as shown in figure subject to three phase symmetrical fault occurred at bus 2 and compare voltages at different buses to analyze effects of faults on neighboring buses. Analyze contribution of adjacent buses in terms of fault currents and Compare currents flowing in the lines connecting different buses of three phase power system. Pre fault voltage at each bus is Vr = 1 + 0j = 1 < 0°. Pre fault currents are assumed to be zero. j4 j2 j3 j1 Zbus = j1 j2.55 j1.67 lji j1.67 j1 j3
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Thermistors
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,