An office is to be air conditioning for 50 employees when the outdoor conditions are 30 C° DBT and 75 % RH. If the quantity of outdoor air supplied is 0.4 m /min/person. Assume that required comfort conditions are 20 C° DBT and 60 % RH and the air is conditioned first by cooling and dehumidification until saturation and then heating. Draw the pshychrometric figure for the processes and find the following: 1- Capacity of the cooling coil in tons of refrigeration. 2- Amount of water removed by the eliminator per hour. 3- If the heating coil surface temperature is 25 C° then find the by-pass factor of the heating coil.

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
An office is to be air conditioning for 50 employees when the outdoor conditions are 30 C°
DBT and 75 % RH. If the quantity of outdoor air supplied is 0.4 m' /min/person. Assume
that required comfort conditions are 20 C° DBT and 60 % RH and the air is conditioned
first by cooling and dehumidification until saturation and then heating. Draw the
pshychrometric figure for the processes and find the following:
1- Capacity of the cooling coil in tons of refrigeration.
2- Amount of water removed by the eliminator per hour.
3- If the heating coil surface temperature is 25 C° then find the by-pass factor of the
heating coil.
Transcribed Image Text:An office is to be air conditioning for 50 employees when the outdoor conditions are 30 C° DBT and 75 % RH. If the quantity of outdoor air supplied is 0.4 m' /min/person. Assume that required comfort conditions are 20 C° DBT and 60 % RH and the air is conditioned first by cooling and dehumidification until saturation and then heating. Draw the pshychrometric figure for the processes and find the following: 1- Capacity of the cooling coil in tons of refrigeration. 2- Amount of water removed by the eliminator per hour. 3- If the heating coil surface temperature is 25 C° then find the by-pass factor of the heating coil.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 6 steps with 10 images

Blurred answer
Knowledge Booster
Work and Heat
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY