An industrial plant is supplied by a power utility company with voltage of 7.97 kV. To monitor the plant's performance and consumption, the utility company installed a potential transformer (PT) and a current transformer (CT) at the plant's premises. The specs of the transformers are as shown on Figure 1. The plant is drawing 2000 kW at 0.90 pf lagging,. Industrial Plant IA CB A VL = 7.97 kV PT CT (V) 1 kn 250 ΜΩ PT Specs: 7970-V:120-V, 60 Hz X₁ = 1721 02, R₂ = 1378 , X = 782 k X₂ = 1897 22, R₂ = 1602 (referred to its primary) CT Specs: 200-A:5-A, 60 Hz X, = 745 μΩ, R, = 136 μΩ, Χ = 307 ΜΩ X'₂ = 813 μn, R'₂=128 un (referred to its primary) ...

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

What is the magnitude of the line current drawn by the plant in amperes?

An industrial plant is supplied by a power utility company with voltage of 7.97 kV. To monitor the plant's performance and
consumption, the utility company installed a potential transformer (PT) and a current transformer (CT) at the plant's premises. The
specs of the transformers are as shown on Figure 1. The plant is drawing 2000 kW at 0.90 pf lagging,.
Industrial
Plant
CBA
VL = 7.97 kV
PT
CT
1 ΚΩ
250 μΩ
PT Specs:
7970-V:120-V, 60 Hz
X, = 1721 Ω, R, = 1378 Ω, Χ = 782 ΚΩ
X'₂ = 1897 02, R₂ = 1602 2 (referred to its primary)
CT Specs:
200-A:5-A, 60 Hz
X, = 745 μΩ, R, = 136 μΩ, X = 307 ΜΩ
X'₂ = 813 μn, R'₂=128 µn (referred to its primary)
Transcribed Image Text:An industrial plant is supplied by a power utility company with voltage of 7.97 kV. To monitor the plant's performance and consumption, the utility company installed a potential transformer (PT) and a current transformer (CT) at the plant's premises. The specs of the transformers are as shown on Figure 1. The plant is drawing 2000 kW at 0.90 pf lagging,. Industrial Plant CBA VL = 7.97 kV PT CT 1 ΚΩ 250 μΩ PT Specs: 7970-V:120-V, 60 Hz X, = 1721 Ω, R, = 1378 Ω, Χ = 782 ΚΩ X'₂ = 1897 02, R₂ = 1602 2 (referred to its primary) CT Specs: 200-A:5-A, 60 Hz X, = 745 μΩ, R, = 136 μΩ, X = 307 ΜΩ X'₂ = 813 μn, R'₂=128 µn (referred to its primary)
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Follow-up Questions
Read through expert solutions to related follow-up questions below.
Follow-up Question

What is the magnitude in kilo-ohms of the PT?

 
Round your answer to 1 decimal place.
Solution
Bartleby Expert
SEE SOLUTION
Knowledge Booster
Electric heating unit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,