An axial centric force of magnitude P= 410 kN is applied to the composite block shown by means of a rigid end plate. It is given that h = 10 mm. Brass core (E = 105 GPa) Ahuminum plates (E = 70 GPa) Rigid end plate 300 mm 60 mm 40 mm Determine the normal stress in the brass core. The normal stress in the brass core is MPа.
An axial centric force of magnitude P= 410 kN is applied to the composite block shown by means of a rigid end plate. It is given that h = 10 mm. Brass core (E = 105 GPa) Ahuminum plates (E = 70 GPa) Rigid end plate 300 mm 60 mm 40 mm Determine the normal stress in the brass core. The normal stress in the brass core is MPа.
Related questions
Question
100%

Transcribed Image Text:An axial centric force of magnitude P= 410 kN is applied to the composite block shown by means of a rigid end plate. It is
given that h = 10 mm.
Brass core
(E = 105 GPa)
Ahuminum plates
(E = 70 GPa)
Rigid
end plate
300 mm
60 mm
40 mm
Determine the normal stress in the brass core.
The normal stress in the brass core is
MPа.