An auditorium secats 1,500 persons. The inside design condition is 26°C dry bulb and 17° bulb temperatures. The outside dry bulb temperature is 35°C and the relative humidity is heat gain rate due to walls; roof, windows, etc. is 35 kW. The light power is 15 kW and the Fuis 0.82. culate the followings: lass flow rate of ventilation air required. ooling load due to ventilation air. otal heating load due to occupants for evening show, assuning (CLF =0.76.

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
An auditorium scats 1,500 persons. The inside design condition is 26°C dry bulb and 17°C we
bulb temperatures. The outside dry bulb temperature is 35°C and the relative humidity is 50%
The heat gain rate due to walls; roof, windows, etc. is 35 kW. The light power is 15 kW and the
(CLF)L, is 0.82.
Calculate the followings:
(a) Mass flow rate of ventilation air required.
(b) Cooling load due to ventilation air.
(c) Total heating load due to occupants for evening show, assuning (CLF)oce. = 0.76.
(d) Relative humidity inside the auditorium.
(e) Maximum relative humidity allowed for comfort if the inside dry bulb temperature is to be
maintained at 26°C.
(f) Sensible heat ratio of the auditorium.
Transcribed Image Text:An auditorium scats 1,500 persons. The inside design condition is 26°C dry bulb and 17°C we bulb temperatures. The outside dry bulb temperature is 35°C and the relative humidity is 50% The heat gain rate due to walls; roof, windows, etc. is 35 kW. The light power is 15 kW and the (CLF)L, is 0.82. Calculate the followings: (a) Mass flow rate of ventilation air required. (b) Cooling load due to ventilation air. (c) Total heating load due to occupants for evening show, assuning (CLF)oce. = 0.76. (d) Relative humidity inside the auditorium. (e) Maximum relative humidity allowed for comfort if the inside dry bulb temperature is to be maintained at 26°C. (f) Sensible heat ratio of the auditorium.
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY