Air at 40° C dry bulb temperature and 15% relative humidity is passed through an adiabatic humidifier at the rate of 200 m3/min. The outlet conditions of air are 25°C dry bulb temperature and 20° C wet-bulb temperature. Find. (a) dew point temperature; (b) relative humidity of exit air; and (c) amount of water vapor added to the air per minute. [Ans. 17.8° C; 65%: 1.26 kg /min]!
Air at 40° C dry bulb temperature and 15% relative humidity is passed through an adiabatic humidifier at the rate of 200 m3/min. The outlet conditions of air are 25°C dry bulb temperature and 20° C wet-bulb temperature. Find. (a) dew point temperature; (b) relative humidity of exit air; and (c) amount of water vapor added to the air per minute. [Ans. 17.8° C; 65%: 1.26 kg /min]!
Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
Related questions
Question
![Air at 40° C dry bulb temperature and 15% relative humidity is passed through
an adiabatic humidifier at the rate of 200 ms/min. The outlet conditions of air are
25°C dry bulb temperature and 20° C wet-bulb temperature. Find. (a) dew point
temperature; (b) relative humidity of exit air; and (c) amount of water vapor added
to the air per minute. [Ans. 17.8° C; 65%: 1.26 kg /min].](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F7f90dc32-25cc-4597-8236-f12701d1179e%2Fbb6bbda7-8a58-4c86-93c4-584d75e94579%2Fdc67pco_processed.jpeg&w=3840&q=75)
Transcribed Image Text:Air at 40° C dry bulb temperature and 15% relative humidity is passed through
an adiabatic humidifier at the rate of 200 ms/min. The outlet conditions of air are
25°C dry bulb temperature and 20° C wet-bulb temperature. Find. (a) dew point
temperature; (b) relative humidity of exit air; and (c) amount of water vapor added
to the air per minute. [Ans. 17.8° C; 65%: 1.26 kg /min].
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 4 steps

Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you

Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press

Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON

Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education

Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press

Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON

Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education

Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY

Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning

Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY