A vapor-compression refrigeration system is conventional except that a countercurrent heat exchanger is installed to subcool the liquid from the condenser by heat exchange with the vapor stream from the evaporator. The minimum temperature difference for heat transfer is 5°C. Tetrafluoroethane is the refrigerant (Table 9.1, Fig. F.2), evaporating at -8°C and condensing at 24 °C. The heat load on the evaporator is 2000 kJ/s.

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
kindly answer this chemical engineering thermodynamics problem SKETCH/DRAW necessary diagrams and illustrations. State all assumptions, conditions and conclusions properly. Thank you so much
(a) If the compressor efficiency is 72%, what is the power requirement? *
DONE
(b) How does this result compare with the power required by the compressor if
the system operates without the heat exchanger? *
O DONE
(c) How do the refrigerant circulation rates cómpare for the two cases? *
OS DONEanned with CamScanner
Transcribed Image Text:(a) If the compressor efficiency is 72%, what is the power requirement? * DONE (b) How does this result compare with the power required by the compressor if the system operates without the heat exchanger? * O DONE (c) How do the refrigerant circulation rates cómpare for the two cases? * OS DONEanned with CamScanner
A vapor-compression refrigeration system is conventional except that a countercurrent heat exchanger is
installed to subcool the liquid from the condenser by heat exchange with the vapor stream from the
evaporator. The minimum temperature difference for heat transfer is 5°C. Tetrafluoroethane is the
refrigerant (Table 9.1, Fig. F.2), evaporating at -8°C and condensing at 24 °C. The heat load on the
evaporator is 2000 kJ/s.
Transcribed Image Text:A vapor-compression refrigeration system is conventional except that a countercurrent heat exchanger is installed to subcool the liquid from the condenser by heat exchange with the vapor stream from the evaporator. The minimum temperature difference for heat transfer is 5°C. Tetrafluoroethane is the refrigerant (Table 9.1, Fig. F.2), evaporating at -8°C and condensing at 24 °C. The heat load on the evaporator is 2000 kJ/s.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The