A three-phase Y-connected 230-V (line-to-line) 7.5-kW 60-Hz six-pole induction motor has the following parameter values in Ω/phase referred to the stator: R1 = 0.294, R2 = 0.144 X1 = 0.503, X2 = 0.209, Xm = 13.25 The total friction, windage, and core losses may be assumed to be constant at 403 W, independent of load. For a slip of 4 percent, determine: (a) stator current, power factor, (b) output torque and power, (c) efficiency when the motor is operated at rated voltage and frequency,
A three-phase Y-connected 230-V (line-to-line) 7.5-kW 60-Hz six-pole induction motor has the following parameter values in Ω/phase referred to the stator: R1 = 0.294, R2 = 0.144 X1 = 0.503, X2 = 0.209, Xm = 13.25
The total friction, windage, and core losses may be assumed to be constant at 403 W, independent of load. For a slip of 4 percent, determine:
(a) stator current, power factor,
(b) output torque and power,
(c) efficiency when the motor is operated at rated voltage and frequency,
(d) the load component 12 of the stator current, the induced torque Tind, and the converted power Pconv for a slip s= 0.04,
(e) the maximum torque and the corresponding speed; and
(f) the starting torque Tst and the corresponding stator load current 12 start
Step by step
Solved in 3 steps with 1 images