A three-phase induction motor nameplate has the following information: 10 hp 60HZ 229 V 26 A 1743 rpm 215T frame Class B Code F SF 1.15 Stator is Y connected. Account for increased conductor resistance during ac operation by letting the value of R1 be 1.05 times the value of R1 obtained from the dc test. Recorded test data are known where voltages are measured line-to-line and po" values are total three-phase: DC Test: 5 V 22 A Blocked Rotor Test: 22 V, 26 A, 753 W, 15 Hz No-Load Test: 229 V, 10 A, 791 W, 1797 rpm Emplricol dislribulon of X NEMA Deulgn X1 X5 0.5X 05X 0.6X 0.7X 0.4X 0.3X 05X4 05. 05X Wound rotor 0.5X Find X1 and X2

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
please solve asap.
A three-phase induction motor nameplate has the following information:
10 hp 60HZ
229 V
26 A
1743 rpm
215T frame Class B
Code F
SF 1.15
Stator is Y connected.
Account for increased conductor resistance during ac operation by letting the
value of R1 be 1.05 times the value of R1 obtained from the dc test.
Recorded test data are known where voltages are measured line-to-line and pov
values are total three-phase:
DC Test: 5 V , 22 A
Blocked Rotor Test: 22 V , 26 A, 753 W, 15 Hz
No-Load Test: 229 V, 10 A, 791 W , 1797 rpm
Emplricol distribulon of X
NEMA Dealgn
X5
0.5X
0.4X
0.3X
05X
0.6X
0.7X
05X
05X
Wound rotor
05X
0.5X
Find X1 and X2
Transcribed Image Text:A three-phase induction motor nameplate has the following information: 10 hp 60HZ 229 V 26 A 1743 rpm 215T frame Class B Code F SF 1.15 Stator is Y connected. Account for increased conductor resistance during ac operation by letting the value of R1 be 1.05 times the value of R1 obtained from the dc test. Recorded test data are known where voltages are measured line-to-line and pov values are total three-phase: DC Test: 5 V , 22 A Blocked Rotor Test: 22 V , 26 A, 753 W, 15 Hz No-Load Test: 229 V, 10 A, 791 W , 1797 rpm Emplricol distribulon of X NEMA Dealgn X5 0.5X 0.4X 0.3X 05X 0.6X 0.7X 05X 05X Wound rotor 05X 0.5X Find X1 and X2
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps

Blurred answer
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,