G1 T1 BUS1 5MVA 10/110kV 30%X BUS3 T3 10MVA 110/4.16kV 30%X M5MVA 4KV 18%X G2 22 T2 3MVA 4.16/110kV 10%X BUS2 BUS4 A three phase, four-bus system is shown at figure 2. The transmission line per-unit impedances are as follows: Rating (MVA) VOLTAGE (KV) IMPEDANCE (pu) LINE 1-2 100 110 0.01+j0.5 1-3 100 110 0.1+j2 2-3 100 110 0.15+j3 2-4 100 110 0.1+j2 3-4 100 110 0.01+j0.5 Generator 1 has a nameplate rating of 10MVA, 10kV with 20%X and generator 2 has a nameplate rating of 5MVA, 4.16kV with 8%X. Including motor contribution, if the pre-fault voltage at the terminals of the motor is 4kV, determine: (a) the symmetrical fault at the terminals of the motor in Amperes; (b) the short circuit MVA at the terminals of the motor.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

Please answer this diligently. Other answers in the internet seems wrong. Please help me understand and solve this problem. I'll give a like. Thanks!

Isc = __________; MVAsc = __________

G1
T1
BUS1
5MVA
10/110kV
30%X
BUS3
T3
10MVA
110/4.16kV
30%X
M5MVA
4KV
18%X
G2
22
T2
3MVA
4.16/110kV
10%X
BUS2
BUS4
Transcribed Image Text:G1 T1 BUS1 5MVA 10/110kV 30%X BUS3 T3 10MVA 110/4.16kV 30%X M5MVA 4KV 18%X G2 22 T2 3MVA 4.16/110kV 10%X BUS2 BUS4
A three phase, four-bus system is shown at figure 2. The transmission line per-unit impedances are as
follows:
Rating (MVA) VOLTAGE (KV) IMPEDANCE (pu)
LINE
1-2
100
110
0.01+j0.5
1-3
100
110
0.1+j2
2-3
100
110
0.15+j3
2-4
100
110
0.1+j2
3-4
100
110
0.01+j0.5
Generator 1 has a nameplate rating of 10MVA, 10kV with 20%X and generator 2 has a nameplate rating
of 5MVA, 4.16kV with 8%X. Including motor contribution, if the pre-fault voltage at the terminals of the
motor is 4kV, determine: (a) the symmetrical fault at the terminals of the motor in Amperes; (b) the
short circuit MVA at the terminals of the motor.
Transcribed Image Text:A three phase, four-bus system is shown at figure 2. The transmission line per-unit impedances are as follows: Rating (MVA) VOLTAGE (KV) IMPEDANCE (pu) LINE 1-2 100 110 0.01+j0.5 1-3 100 110 0.1+j2 2-3 100 110 0.15+j3 2-4 100 110 0.1+j2 3-4 100 110 0.01+j0.5 Generator 1 has a nameplate rating of 10MVA, 10kV with 20%X and generator 2 has a nameplate rating of 5MVA, 4.16kV with 8%X. Including motor contribution, if the pre-fault voltage at the terminals of the motor is 4kV, determine: (a) the symmetrical fault at the terminals of the motor in Amperes; (b) the short circuit MVA at the terminals of the motor.
AI-Generated Solution
AI-generated content may present inaccurate or offensive content that does not represent bartleby’s views.
steps

Unlock instant AI solutions

Tap the button
to generate a solution

Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,