A simply supported beam is subjected to a uniform service dead load of 1.0 kips/ft (including the weight of the beam), a uniform service live load of 2.0 kips/ft, and a concentrated service dead load of 40 kips. The beam is 40 feet long, and the concentrated load is located 15 feet from the left end. The beam has continuous lateral support, and A572 Grade 50 steel is used. Is a W30 x 108 adequate? a. Use LRFD. b. Use ASD. PD = 40 k 25'- = WD WL 1.0 k/ft = 2.0 k/ft = 15'- W30 X 108 40'-

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question

5.5-3 A simplrted beam is subjected to a uniform service dead load of 1.0 kip cluding the weight of the beam), a uniform service live load of 0 kipft, and a concentrated service dead load of 40 kips. The beam feet long, and the concentrated load is located 15 feet from the left The beam has continuous lateral support, and A572 Grade 50 steel is used. Is a W30 x 108 adequate

a. Use LRFD.

b. Use ASD.

A simply supported beam is subjected to a uniform service dead load of
1.0 kips/ft (including the weight of the beam), a uniform service live load
of 2.0 kips/ft, and a concentrated service dead load of 40 kips. The beam
is 40 feet long, and the concentrated load is located 15 feet from the left
end. The beam has continuous lateral support, and A572 Grade 50 steel is
used. Is a W30 × 108 adequate?
a. Use LRFD.
b. Use ASD.
PD = 40 k
25'-
WD
1.0 k/ft
= 2.0 k/ft
=
WL
15'-
W30 X 108
40'-
Transcribed Image Text:A simply supported beam is subjected to a uniform service dead load of 1.0 kips/ft (including the weight of the beam), a uniform service live load of 2.0 kips/ft, and a concentrated service dead load of 40 kips. The beam is 40 feet long, and the concentrated load is located 15 feet from the left end. The beam has continuous lateral support, and A572 Grade 50 steel is used. Is a W30 × 108 adequate? a. Use LRFD. b. Use ASD. PD = 40 k 25'- WD 1.0 k/ft = 2.0 k/ft = WL 15'- W30 X 108 40'-
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Design criteria for structural loading
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning