A silver (Ag) electroplating plant producing a wastewater stream contains 5 wt% Ag which need to be treated before disposal. The wastewater is fed to a treatment tour where 95% of the fed Ag is recovered, while residual liquid water is sent to waste pond. Maximum capacity of the treatment tour is 6000 kg wastewater/hr. When the fed wastewater stream at a rate higher then the capacity of the treatment tour, the excess wastewater bypass the unit and combines with the residual liquid water from the treatment tour and goes to the waste pond. Initially flowrate of the fed wastewater (Mo) is in the range of 4000-5000 kg/h, suddenly after 30 hours the flowrate varies according to a linear equation, M (kg fed wastewater at time t) = 50t (hr) + Mo(initial wastewater flowrate). The linear flowrate continue according to the equation, however after 60 hours the flowrate has reached its steady state and continue at constant flowrate value. Choose one Mo from the given range, draw process flow diagram of the system an determine composition of each stream for the three M conditions (initial flowrate, linea flowrate and constant flowrate).

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
please help me this question im really need the ans ?
A silver (Ag) electroplating plant producing a wastewater stream contains 5 wt% Ag which
need to be treated before disposal. The wastewater is fed to a treatment tour where 95% of
the fed Ag is recovered, while residual liquid water is sent to waste pond. Maximum capacity
of the treatment tour is 6000 kg wastewater/hr. When the fed wastewater stream at a rate
higher then the capacity of the treatment tour, the excess wastewater bypass the unit and
combines with the residual liquid water from the treatment tour and goes to the waste pond.
Initially flowrate of the fed wastewater (Mo) is in the range of 4000-5000 kg/h, suddenly
after 30 hours the flowrate varies according to a linear equation,
M (kg fed wastewater at time t) = 50t (hr) + Mo(initial wastewater flowrate).
The linear flowrate continue according to the equation, however after 60 hours the flowrate
has reached its steady state and continue at constant flowrate value.
Choose one Mo from the given range, draw process flow diagram of the system and
determine composition of each stream for the three M conditions (initial flowrate, linear
flowrate and constant flowrate).
Transcribed Image Text:A silver (Ag) electroplating plant producing a wastewater stream contains 5 wt% Ag which need to be treated before disposal. The wastewater is fed to a treatment tour where 95% of the fed Ag is recovered, while residual liquid water is sent to waste pond. Maximum capacity of the treatment tour is 6000 kg wastewater/hr. When the fed wastewater stream at a rate higher then the capacity of the treatment tour, the excess wastewater bypass the unit and combines with the residual liquid water from the treatment tour and goes to the waste pond. Initially flowrate of the fed wastewater (Mo) is in the range of 4000-5000 kg/h, suddenly after 30 hours the flowrate varies according to a linear equation, M (kg fed wastewater at time t) = 50t (hr) + Mo(initial wastewater flowrate). The linear flowrate continue according to the equation, however after 60 hours the flowrate has reached its steady state and continue at constant flowrate value. Choose one Mo from the given range, draw process flow diagram of the system and determine composition of each stream for the three M conditions (initial flowrate, linear flowrate and constant flowrate).
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Convection
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY