A long thin-walled double-pipe heat exchanger with tube and shell diameters of 1.5 cm and 3 cm, respectively, is used to condense refrigerant 134-a by water at 25°C. Water flows through the shell at a rate of 0.5 kg/s. The refrigerant flows through the tube, with a convection heat transfer coefficient of hi=4000 W/m2·°C. Also, 3-mm-thick layer of limestone (k=1.3 W/m·°C) forms on the outer surface of the inner tube. Determine the overall heat transfer coefficient of this heat exchanger.
Heat Exchangers
Heat exchangers are the types of equipment that are primarily employed to transfer the thermal energy from one fluid to another, provided that one of the fluids should be at a higher thermal energy content than the other fluid.
Heat Exchanger
The heat exchanger is a combination of two words ''Heat'' and ''Exchanger''. It is a mechanical device that is used to exchange heat energy between two fluids.
A long thin-walled double-pipe heat exchanger with tube and shell diameters of 1.5 cm and 3 cm, respectively, is used to condense refrigerant 134-a by water at 25°C. Water flows through the shell at a rate of 0.5 kg/s. The refrigerant flows through the tube, with a convection heat transfer coefficient of hi=4000 W/m2·°C. Also, 3-mm-thick layer of limestone (k=1.3 W/m·°C) forms on the outer surface of the inner tube. Determine the overall heat transfer coefficient of this heat exchanger.
Trending now
This is a popular solution!
Step by step
Solved in 5 steps