A long homogeneous resistance wire of radius ro = 2 cm, and thermal conductivity k = 25 W/m°C is being used to boil water. Heat is generated in the wire uniformly as a result of resistance heating at a rate of q'=10x105 W/m. If the outer surface temperature of the wire is measured to be Ts = 120 °C, obtain a relation for the temperature distribution, and determine the temperature at the centerline of the wire for steady operating conditions

icon
Related questions
Question

A long homogeneous resistance wire of radius ro = 2 cm, and thermal conductivity k = 25 W/m°C is
being used to boil water. Heat is generated in the wire uniformly as a result of resistance heating at a rate of q'=10x105 W/m.

If the outer surface temperature of the wire is measured to be Ts = 120 °C, obtain a relation for the temperature distribution, and determine the temperature at the centerline of the wire for steady operating conditions

 

dT(0)
= 0
dr
T(r)
TA
01
Transcribed Image Text:dT(0) = 0 dr T(r) TA 01