A flow meter sensor is connected to the microcontroller card to convert the signal and display it as a volume flow rate (L/min.) on the data show screen. Standard volume (graduated cylinder) with stopwatch were employed to calibrate the assemble system, and the calibration results were tabulated as following: Measuri L/min. 51 52 54.5 57 68 73 74 ng value Real L/min. 53 55 57 64 71 76 80 value Determine: 1- Absolute relative error (ARE). 2- Mean value, deviation (error) value and standard deviation (a). 3- Draw the calibration curve.
A flow meter sensor is connected to the microcontroller card to convert the signal and display it as a volume flow rate (L/min.) on the data show screen. Standard volume (graduated cylinder) with stopwatch were employed to calibrate the assemble system, and the calibration results were tabulated as following: Measuri L/min. 51 52 54.5 57 68 73 74 ng value Real L/min. 53 55 57 64 71 76 80 value Determine: 1- Absolute relative error (ARE). 2- Mean value, deviation (error) value and standard deviation (a). 3- Draw the calibration curve.
Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
Related questions
Question
![A flow meter sensor is connected to the microcontroller card to convert the signal and
display it as a volume flow rate (L/min.) on the data show screen. Standard volume
(graduated cylinder) with stopwatch were employed to calibrate the assemble system, and
the calibration results were tabulated as following:
Measuri L/min. 51
52
54.5
57
68
73
74
ng value
Real
L/min. 53
55
57
64
71
76
80
value
Determine:
1- Absolute relative error (ARE).
2- Mean value, deviation (error) value and standard deviation (a).
3- Draw the calibration curve.](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F6577ce23-d4a0-46f0-92a9-4e2612d00a89%2Fc9dfef83-bdc0-4e9e-b05f-35e4ed986034%2Fio56hu6_processed.jpg&w=3840&q=75)
Transcribed Image Text:A flow meter sensor is connected to the microcontroller card to convert the signal and
display it as a volume flow rate (L/min.) on the data show screen. Standard volume
(graduated cylinder) with stopwatch were employed to calibrate the assemble system, and
the calibration results were tabulated as following:
Measuri L/min. 51
52
54.5
57
68
73
74
ng value
Real
L/min. 53
55
57
64
71
76
80
value
Determine:
1- Absolute relative error (ARE).
2- Mean value, deviation (error) value and standard deviation (a).
3- Draw the calibration curve.
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 5 steps with 13 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Recommended textbooks for you
![Introductory Circuit Analysis (13th Edition)](https://www.bartleby.com/isbn_cover_images/9780133923605/9780133923605_smallCoverImage.gif)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
![Delmar's Standard Textbook Of Electricity](https://www.bartleby.com/isbn_cover_images/9781337900348/9781337900348_smallCoverImage.jpg)
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
![Programmable Logic Controllers](https://www.bartleby.com/isbn_cover_images/9780073373843/9780073373843_smallCoverImage.gif)
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
![Introductory Circuit Analysis (13th Edition)](https://www.bartleby.com/isbn_cover_images/9780133923605/9780133923605_smallCoverImage.gif)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
![Delmar's Standard Textbook Of Electricity](https://www.bartleby.com/isbn_cover_images/9781337900348/9781337900348_smallCoverImage.jpg)
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
![Programmable Logic Controllers](https://www.bartleby.com/isbn_cover_images/9780073373843/9780073373843_smallCoverImage.gif)
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
![Fundamentals of Electric Circuits](https://www.bartleby.com/isbn_cover_images/9780078028229/9780078028229_smallCoverImage.gif)
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
![Electric Circuits. (11th Edition)](https://www.bartleby.com/isbn_cover_images/9780134746968/9780134746968_smallCoverImage.gif)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
![Engineering Electromagnetics](https://www.bartleby.com/isbn_cover_images/9780078028151/9780078028151_smallCoverImage.gif)
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,