A drinking water treatment plant with conventional treatment uses on disinfection segment consisting of a rectangular basin, with a theoretical detention of 270 min with a baffling factor of 0.5. The average free chlorine residual recorded at the disinfection segment monitoring location in 1.6 mg/L. The lowest free chlorine residual recorded was 1.2 mg/L during peak flow. The water temperature is 5C and pH is 7.5  a) Determine the inactivation ratio if 0.5-log inactivation of Giardia lamblia cysts is required  b) Under these design conditions, have Giardia lamblia cysts been adequently inactivated?  c) Will the plant achieve adequete Giardia lamblia inactivation if 0.5-log inactivation is required but the water temperature is raised to 10C? d) Will the plant achieve adequete Giardia lamblia inactivation if 3-log inactivation is required and the water temperature remain at 5C? e) Will the plant achieve adequete Giardia lamblia inactivation if 3-log inactivation is required and the water temperature is raised to 10C

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question

A drinking water treatment plant with conventional treatment uses on disinfection segment consisting of a rectangular basin, with a theoretical detention of 270 min with a baffling factor of 0.5. The average free chlorine residual recorded at the disinfection segment monitoring location in 1.6 mg/L. The lowest free chlorine residual recorded was 1.2 mg/L during peak flow. The water temperature is 5C and pH is 7.5 

a) Determine the inactivation ratio if 0.5-log inactivation of Giardia lamblia cysts is required 

b) Under these design conditions, have Giardia lamblia cysts been adequently inactivated? 

c) Will the plant achieve adequete Giardia lamblia inactivation if 0.5-log inactivation is required but the water temperature is raised to 10C?

d) Will the plant achieve adequete Giardia lamblia inactivation if 3-log inactivation is required and the water temperature remain at 5C?

e) Will the plant achieve adequete Giardia lamblia inactivation if 3-log inactivation is required and the water temperature is raised to 10C

Expert Solution
steps

Step by step

Solved in 6 steps with 4 images

Blurred answer
Knowledge Booster
Storm sewers and detention
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning