A drilled shaft designed in accordance with the AASHTO code must support the following downward and uplift axial design loads: P = 850 k, Pup. = 270 k. The soil profile consists of: Undrained Shear Strength, s,, (lb/ft²) Depth (ft) Soil Description Unit Weight, y (lb/ft³) N60 0-15 Clayey silt 115 1200 15-35 Silty clay 112 1800 35-55 Sandy silt (nonplastic) 115 24 55-80 Silty sand 124 43 Practice Problems 597 The groundwater is at a depth of 50 ft. Using the AASHTO resistance factors, select a diameter and depth for a single drilled shaft to support these design loads. Use a load factor of 0.9 on the weight of the shaft. Note there are many different diameter-length combinations that would be satisfactory, but select one that you think would be most appropriate.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
icon
Concept explainers
Question
100%
A drilled shaft designed in accordance with the AASHTO code must support the following
downward and uplift axial design loads: P = 850 k, Pup. = 270 k. The soil profile consists of:
Undrained Shear
Strength, s,, (lb/ft²)
Depth (ft)
Soil Description
Unit Weight, y (lb/ft³)
N60
0-15
Clayey silt
115
1200
15-35
Silty clay
112
1800
35-55 Sandy silt (nonplastic)
115
24
55-80
Silty sand
124
43
Practice Problems
597
The groundwater is at a depth of 50 ft. Using the AASHTO resistance factors, select a diameter
and depth for a single drilled shaft to support these design loads. Use a load factor of 0.9 on the
weight of the shaft. Note there are many different diameter-length combinations that would
be satisfactory, but select one that you think would be most appropriate.
Transcribed Image Text:A drilled shaft designed in accordance with the AASHTO code must support the following downward and uplift axial design loads: P = 850 k, Pup. = 270 k. The soil profile consists of: Undrained Shear Strength, s,, (lb/ft²) Depth (ft) Soil Description Unit Weight, y (lb/ft³) N60 0-15 Clayey silt 115 1200 15-35 Silty clay 112 1800 35-55 Sandy silt (nonplastic) 115 24 55-80 Silty sand 124 43 Practice Problems 597 The groundwater is at a depth of 50 ft. Using the AASHTO resistance factors, select a diameter and depth for a single drilled shaft to support these design loads. Use a load factor of 0.9 on the weight of the shaft. Note there are many different diameter-length combinations that would be satisfactory, but select one that you think would be most appropriate.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Load and resistance factor design
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning