A distance offset mho relay used amplitude comparator using current transformer (CT) with ratio of 5000/1 and voltage transformer (VT) with ratio 1200/1. The relay having circuit impedance of ZR = 20245° ohms and ratio of transformer turns of 0.4. Calculate the reach distance of the relay when line impedance is 0.5/80° ohms per phase per kilometer. a. An arching short circuit fault occurs at 10.2 km anywhere on the line, calculate the maximum portion of the line that can be protected. a.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

protection system

pls answer step by step

A distance offset mho relay used amplitude comparator using current transformer (CT)
with ratio of 5000/1 and voltage transformer (VT) with ratio 1200/1. The relay having
circuit impedance of ZR = 20245° ohms and ratio of transformer turns of 0.4.
Calculate the reach distance of the relay when line impedance is 0.5/80° ohms per
phase per kilometer.
a.
An arching short circuit fault occurs at 10.2 km anywhere on the line, calculate the
maximum portion of the line that can be protected.
a.
Transcribed Image Text:A distance offset mho relay used amplitude comparator using current transformer (CT) with ratio of 5000/1 and voltage transformer (VT) with ratio 1200/1. The relay having circuit impedance of ZR = 20245° ohms and ratio of transformer turns of 0.4. Calculate the reach distance of the relay when line impedance is 0.5/80° ohms per phase per kilometer. a. An arching short circuit fault occurs at 10.2 km anywhere on the line, calculate the maximum portion of the line that can be protected. a.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 4 images

Blurred answer
Knowledge Booster
Infinite Impulse Response (IIR) and Finite Impulse Response (FIR) Filter
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,