) A conventional consolidated drained (CD) triaxial test was conducted on saturated clean sand sample by using the following steps : (1) Set cell pressure to 250 kPa and allow the sample to consolidate with its drainage valve open at 100 kPa back pressure. (2) Shear the sample without any change in the drainage condition. The sample failed when the deviator stress reached 300 kPa. Use analytical solution to determine: (1) The slope of failure envelope in degrees. Assume c' to be zero. (ii) Slope of the failure plane in degrees. (iii) Shear stress and normal stress on the failure plane (in kPa). (iv) The maximum shear stress at failure (in kPa).

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
I need the answer quickly
(a) A conventional consolidated drained (CD) triaxial test was conducted on saturated clean sand
sample by using the following steps :
(1) Set cell pressure to 250 kPa and allow the sample to consolidate with its drainage valve
open at 100 kPa back pressure.
(2) Shear the sample without any change in the drainage condition.
The sample failed when the deviator stress reached 300 kPa. Use analytical solution to
determine:
(1) The slope of failure envelope in degrees. Assume e' to be zero.
(ii) Slope of the failure plane in degrees.
(iii) Shear stress and normal stress on the failure plane (in kPa).
(iv) The maximum shear stress at failure (in kPa).
Transcribed Image Text:(a) A conventional consolidated drained (CD) triaxial test was conducted on saturated clean sand sample by using the following steps : (1) Set cell pressure to 250 kPa and allow the sample to consolidate with its drainage valve open at 100 kPa back pressure. (2) Shear the sample without any change in the drainage condition. The sample failed when the deviator stress reached 300 kPa. Use analytical solution to determine: (1) The slope of failure envelope in degrees. Assume e' to be zero. (ii) Slope of the failure plane in degrees. (iii) Shear stress and normal stress on the failure plane (in kPa). (iv) The maximum shear stress at failure (in kPa).
Expert Solution
steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Knowledge Booster
Asphalt binders and mixtures
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning