(a) Check if the given connection follows the code provisions on spacing and edge distance limits. (b) Determine the maximum allowable service tensile load that the member is allowed to carry. Consider all applicable limit states for tension member and connection. Consider only block shear and bearing limit state for gusset plate. Use ASD specifications.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question

I NEED IN 2HOURS PLSSS 3 DECIMALS.

(a) Check if the given connection follows the code provisions on spacing and edge distance
limits.
(b) Determine the maximum allowable service tensile load that the member is allowed to
carry. Consider all applicable limit states for tension member and connection. Consider
only block shear and bearing limit state for gusset plate. Use ASD specifications.
Transcribed Image Text:(a) Check if the given connection follows the code provisions on spacing and edge distance limits. (b) Determine the maximum allowable service tensile load that the member is allowed to carry. Consider all applicable limit states for tension member and connection. Consider only block shear and bearing limit state for gusset plate. Use ASD specifications.
Consider the tension member shown below. The channel is made of ASTM A572 (Fy = 50
ksi; Fy = 65 ksi), and is connected to a 3/8-inch thick gusset plate made of ASTM A36
steel (F, = 36 ksi; Fu = 58 ksi). The bolts are 7/8 inch in diameter, made of ASTM A307
bolts. The bolted connection is bearing-type.
2" 3"| 3" | 3"
2"
o o o
2"
C8 X 18.75
– t = 3/8"
Transcribed Image Text:Consider the tension member shown below. The channel is made of ASTM A572 (Fy = 50 ksi; Fy = 65 ksi), and is connected to a 3/8-inch thick gusset plate made of ASTM A36 steel (F, = 36 ksi; Fu = 58 ksi). The bolts are 7/8 inch in diameter, made of ASTM A307 bolts. The bolted connection is bearing-type. 2" 3"| 3" | 3" 2" o o o 2" C8 X 18.75 – t = 3/8"
Expert Solution
steps

Step by step

Solved in 9 steps with 2 images

Blurred answer
Knowledge Booster
Tension members
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning