A certain load varies as follows for 269 days per annum: 436 kVA at a power factor of 0.819 lagging for eight hours per day. 208KVA at a power factor of 0.836 lagging for eight hours per day. 131 kVA at unity power factor for eight hours per day. For the remaining time of the year, the load varies as follows: • 90 kVA at a power factor of 0.822 lagging for eight hours per day. • 25 kVA at a power factor of 0.866 lagging for eight hours per day. • No load for eight hours per day. Determine the average value of the load per annum Determine the annual load factor (KL) Determine the Rms value of the load per annum in kVA Determine the form factor (K)

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question

68 Electrical Technology

A certain load varies as follows for 269 days per annum:
436 kVA at a power factor of 0.819 lagging for eight hours per day.
208KVA at a power factor of 0.836 lagging for eight hours per day.
131 kVA at unity power factor for eight hours per day.
For the remaining time of the year, the load varies as follows:
• 90 kVA at a power factor of 0.822 lagging for eight hours per day.
• 25 kVA at a power factor of 0.866 lagging for eight hours per day.
• No load for eight hours per day.
Determine the average value of the load per annum
Determine the annual load factor (KL)
Determine the Rms value of the load per annum in kVA
Determine the form factor (K)
Transcribed Image Text:A certain load varies as follows for 269 days per annum: 436 kVA at a power factor of 0.819 lagging for eight hours per day. 208KVA at a power factor of 0.836 lagging for eight hours per day. 131 kVA at unity power factor for eight hours per day. For the remaining time of the year, the load varies as follows: • 90 kVA at a power factor of 0.822 lagging for eight hours per day. • 25 kVA at a power factor of 0.866 lagging for eight hours per day. • No load for eight hours per day. Determine the average value of the load per annum Determine the annual load factor (KL) Determine the Rms value of the load per annum in kVA Determine the form factor (K)
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Type of Thyristors
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,