A building has a calculated cooling load of 410 kW. The latent portion of the load is 100 kW. The space is to be maintained at 25 C DBT and 50% RH. Outdoor air at 38 c and 50% RH, and 10% by mass of the air supplied to the space is outdoor air. Air is to be supplied to the space at not less than 18 c. Find:: " a- The minimum amount of air supplied to the space in m³\s, b- The volume flow rates of the return air, exhaust air, and outdoor air, c- The conditions and volume flow rates of the air entering the cooling coil, d- The capacity, apparatus dew point temperature, and by pass factor of the cooling EY S 17 coil..

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
A building has a calculated cooling load of 410 kW. The latent portion of the load is
100 kW. The space is to be maintained at 25 C DBT and 50% RH. Outdoor air at 38 c and
50% RH, and 10% by mass of the air supplied to the space is outdoor air. Air is to be
supplied to the space at not less than 18 c. Find::
S
a- The minimum amount of air supplied to the space in m³\s,
b- The volume flow rates of the return air, exhaust air, and outdoor air,
c- The conditions and volume flow rates of the air entering the cooling coil,
d- The capacity, apparatus dew point temperature, and by pass factor of the cooling
coil.
Transcribed Image Text:A building has a calculated cooling load of 410 kW. The latent portion of the load is 100 kW. The space is to be maintained at 25 C DBT and 50% RH. Outdoor air at 38 c and 50% RH, and 10% by mass of the air supplied to the space is outdoor air. Air is to be supplied to the space at not less than 18 c. Find:: S a- The minimum amount of air supplied to the space in m³\s, b- The volume flow rates of the return air, exhaust air, and outdoor air, c- The conditions and volume flow rates of the air entering the cooling coil, d- The capacity, apparatus dew point temperature, and by pass factor of the cooling coil.
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Work and Heat
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY