A big box retail store is built with CMU bearing walls around its perimeter. The store measures 450 ft across the front and back and 360 ft across the sides. The walls are 28 ft tall and are reinforced horizontally with truss bars in alternate courses and vertically with #4 bars 32 in. on-center. There is an 8” tall bond beam running around the full perimeter of the building at the roof level (24 ft) to support the roof framing. The openings in the CMU walls, and the associated lintels are as follows: Opening Location Quantity Size Lintel Lintel Rebar Door Front wall 2 8’-0” x 10’-0” 16” tall CMU 2, #4 Door Side wall 2 each side 8’-0” x 4’-0” 8” tall CMU 1, #4 Door Back wall 3 8’-0” x 9’-0” 16” tall CMU 2, #4 Window Side wall 2 4’-0” x 3’-0” 8” tall CMU 1, #4 Note: each lintel should be a multiple of 8” long and have 8” of bearing on each side of the opening. Opening sizes are listed as height x width Determine the national average bare cost for the lintels using RSMeans 04 22 10. Determine the national average bare cost to for the bond beams using RSMeans 04 22 10 Determine the national average bare cost for the vertical reinforcing using RSMeans 04 05 19 and associated grout using RSMeans 04 05 16. Use maximum 8 ft long pieces and lap splice the bars at least 30 bar diameters. Include 15% waste for the grout.
A big box retail store is built with CMU bearing walls around its perimeter. The store measures 450 ft across the front and back and 360 ft across the sides. The walls are 28 ft tall and are reinforced horizontally with truss bars in alternate courses and vertically with #4 bars 32 in. on-center. There is an 8” tall bond beam running around the full perimeter of the building at the roof level (24 ft) to support the roof framing. The openings in the CMU walls, and the associated lintels are as follows: Opening Location Quantity Size Lintel Lintel Rebar Door Front wall 2 8’-0” x 10’-0” 16” tall CMU 2, #4 Door Side wall 2 each side 8’-0” x 4’-0” 8” tall CMU 1, #4 Door Back wall 3 8’-0” x 9’-0” 16” tall CMU 2, #4 Window Side wall 2 4’-0” x 3’-0” 8” tall CMU 1, #4 Note: each lintel should be a multiple of 8” long and have 8” of bearing on each side of the opening. Opening sizes are listed as height x width Determine the national average bare cost for the lintels using RSMeans 04 22 10. Determine the national average bare cost to for the bond beams using RSMeans 04 22 10 Determine the national average bare cost for the vertical reinforcing using RSMeans 04 05 19 and associated grout using RSMeans 04 05 16. Use maximum 8 ft long pieces and lap splice the bars at least 30 bar diameters. Include 15% waste for the grout.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
Related questions
Question
- A big box retail store is built with CMU bearing walls around its perimeter. The store measures 450 ft across the front and back and 360 ft across the sides. The walls are 28 ft tall and are reinforced horizontally with truss bars in alternate courses and vertically with #4 bars 32 in. on-center. There is an 8” tall bond beam running around the full perimeter of the building at the roof level (24 ft) to support the roof framing. The openings in the CMU walls, and the associated lintels are as follows:
Opening |
Location |
Quantity |
Size |
Lintel |
Lintel Rebar |
Door |
Front wall |
2 |
8’-0” x 10’-0” |
16” tall CMU |
2, #4 |
Door |
Side wall |
2 each side |
8’-0” x 4’-0” |
8” tall CMU |
1, #4 |
Door |
Back wall |
3 |
8’-0” x 9’-0” |
16” tall CMU |
2, #4 |
Window |
Side wall |
2 |
4’-0” x 3’-0” |
8” tall CMU |
1, #4 |
Note: each lintel should be a multiple of 8” long and have 8” of bearing on each side of the opening. Opening sizes are listed as height x width
- Determine the national average bare cost for the lintels using RSMeans 04 22 10.
- Determine the national average bare cost to for the bond beams using RSMeans 04 22 10
- Determine the national average bare cost for the vertical reinforcing using RSMeans 04 05 19 and associated grout using RSMeans 04 05 16. Use maximum 8 ft long pieces and lap splice the bars at least 30 bar diameters. Include 15% waste for the grout.
- Determine the national average bare cost for the typical CMU using RSMeans 04 22 10.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 8 steps
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning