(a) A balanced delta connected load of (10 + j3)N is connected to a 3-phase, 415V,50HZ supply. Draw the circuit diagram, indicating VRN, VRY and all line currents, and from this calculate: (i) (ii) (iii) The 3 load phase currents (IRY, IYB and IBR). The 3 line currents (IR, Iy and IB). The total real power and power factor at the 3 phase supply. b) An unbel

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
100%
Answer b and c?
Q1 (a) A balanced delta connected load of (10 + j3)N is connected to a 3-phase,
415V,50HZ supply.
Draw the circuit diagram, indicating VRN, VRY and all line currents, and
from this calculate:
(i)
(ii)
(iii)
The 3 load phase currents (IRY, IYB and IBR).
The 3 line currents (IR, Iy and IB).
The total real power and power factor at the 3 phase supply.
An unbalanced 4 wire star connected load consisting of the phase
impedances ZRs (15+j5)N, Zys (10+j0)N and ZBs (18-j6)N is connected to a
3-phase, 440V, 50H7 supply. Draw the circuit diagram ineluding the
implementation of a 2 wattmeter power measurement and from this:
(b)
(i)
(ii)
Calculate the 3 line currents (IR, Iy and IB).
Construct a scaled phasor diagram and using this or otherwise
determine the star/neutral current IsN. Include VRY and VRB on
the phasor diagram.
Calculate the necessary wire diameter for the star/neutral
connection to achieve a current density of 3A/mm².
(ii)
(c)
Determine the total real supply power (W) for Q1(b) based on the 2
wattmeter measurements.
Transcribed Image Text:Q1 (a) A balanced delta connected load of (10 + j3)N is connected to a 3-phase, 415V,50HZ supply. Draw the circuit diagram, indicating VRN, VRY and all line currents, and from this calculate: (i) (ii) (iii) The 3 load phase currents (IRY, IYB and IBR). The 3 line currents (IR, Iy and IB). The total real power and power factor at the 3 phase supply. An unbalanced 4 wire star connected load consisting of the phase impedances ZRs (15+j5)N, Zys (10+j0)N and ZBs (18-j6)N is connected to a 3-phase, 440V, 50H7 supply. Draw the circuit diagram ineluding the implementation of a 2 wattmeter power measurement and from this: (b) (i) (ii) Calculate the 3 line currents (IR, Iy and IB). Construct a scaled phasor diagram and using this or otherwise determine the star/neutral current IsN. Include VRY and VRB on the phasor diagram. Calculate the necessary wire diameter for the star/neutral connection to achieve a current density of 3A/mm². (ii) (c) Determine the total real supply power (W) for Q1(b) based on the 2 wattmeter measurements.
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Digital Modulation Scheme (Amplitude-Shift Keying [ASK], Phase-Shift Keying [PSK], Frequency-Shift Keying [FSK])
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,