A 500kW, 2400V, four-pole, 60Hz, Y connected induction machine has the following equivalent circuit parameters in ohms per phase referred to the stator: R1 = 0.122 Ω; R2 = 0.317 Ω; X1 = 1.364 Ω; X2 = 1.32 Ω; Xm = 45.8 Ω; Rc≈∞ (no core losses) When operating as a motor, supplied from a 2400V source, the machine achieves rated shaft output power (500kW) at a slip of 3.35%. The machine is to be used as a generator, driven by a wind turbine. It will be connected to a distribution system which can be represented by a 2400V infinite bus. a) From the given data calculate the total rotational losses at rated load. b) With the wind turbine driving the induction machine at a slip of -3.2 percent, calculate (i) the electric power output in kW, (ii) the efficiency (electric power output divided by the shaft input mechanical power) in percent, and (iii) the power factor measured at the machine terminals.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question

A 500kW, 2400V, four-pole, 60Hz, Y connected induction machine has the following
equivalent circuit parameters in ohms per phase referred to the stator:
R1 = 0.122 Ω; R2 = 0.317 Ω; X1 = 1.364 Ω; X2 = 1.32 Ω; Xm = 45.8 Ω; Rc≈∞ (no core
losses)
When operating as a motor, supplied from a 2400V source, the machine achieves rated
shaft output power (500kW) at a slip of 3.35%. The machine is to be used as a generator, driven by a wind turbine. It will be connected to a distribution system which can be
represented by a 2400V infinite bus.
a) From the given data calculate the total rotational losses at rated load.
b) With the wind turbine driving the induction machine at a slip of -3.2 percent, calculate
(i) the electric power output in kW,
(ii) the efficiency (electric power output divided by the shaft input mechanical power) in
percent, and
(iii) the power factor measured at the machine terminals.

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 7 steps with 2 images

Blurred answer
Knowledge Booster
Synchronous Motor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,