A 500-MVA 20-kV, 60-Hz synchronous generator with reactances X, = 0.15, X: 0.24; X 1.1 per unit and time constants T, = 0.035, T = 2.0, T= 0.20 s is connected to a circuit breaker. The generator is operating at 5% above rated %3D voltage and at no-load when a bolted three- phase short circuit occurs on the load side of the breaker. The breaker interrupts the fault 3 cycles after fault inception. On abase of 500MVA, 20KV. The subtransient fault current in kA rms is: Answer: I"= 101.0 kA
A 500-MVA 20-kV, 60-Hz synchronous generator with reactances X, = 0.15, X: 0.24; X 1.1 per unit and time constants T, = 0.035, T = 2.0, T= 0.20 s is connected to a circuit breaker. The generator is operating at 5% above rated %3D voltage and at no-load when a bolted three- phase short circuit occurs on the load side of the breaker. The breaker interrupts the fault 3 cycles after fault inception. On abase of 500MVA, 20KV. The subtransient fault current in kA rms is: Answer: I"= 101.0 kA
Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
Related questions
Question
![A 500-MVA 20-kV, 60-Hz synchronous generator
with reactances X, = 0.15, X= 0.24; X=1.1
per unit and time constants T = 0.035, T, = 2.0,
T= 0.20 s is connected to a circuit breaker. The
generator is operating at 5% above rated
%3D
voltage and at no-load when a bolted three-
phase short circuit occurs on the load side of
the breaker. The breaker interrupts the fault 3
cycles after fault inception. On abase of
500MVA, 20KV.
The subtransient fault current in kA rms is:
Answer: I"= 101.0 kA](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2Fd99b6acb-3c56-46a2-8aaf-762988209417%2F1263f749-268d-4134-b013-cbbe13c6eed9%2Fq6cy0t_processed.jpeg&w=3840&q=75)
Transcribed Image Text:A 500-MVA 20-kV, 60-Hz synchronous generator
with reactances X, = 0.15, X= 0.24; X=1.1
per unit and time constants T = 0.035, T, = 2.0,
T= 0.20 s is connected to a circuit breaker. The
generator is operating at 5% above rated
%3D
voltage and at no-load when a bolted three-
phase short circuit occurs on the load side of
the breaker. The breaker interrupts the fault 3
cycles after fault inception. On abase of
500MVA, 20KV.
The subtransient fault current in kA rms is:
Answer: I"= 101.0 kA
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 2 steps with 2 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Introductory Circuit Analysis (13th Edition)](https://www.bartleby.com/isbn_cover_images/9780133923605/9780133923605_smallCoverImage.gif)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
![Delmar's Standard Textbook Of Electricity](https://www.bartleby.com/isbn_cover_images/9781337900348/9781337900348_smallCoverImage.jpg)
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
![Programmable Logic Controllers](https://www.bartleby.com/isbn_cover_images/9780073373843/9780073373843_smallCoverImage.gif)
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
![Introductory Circuit Analysis (13th Edition)](https://www.bartleby.com/isbn_cover_images/9780133923605/9780133923605_smallCoverImage.gif)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
![Delmar's Standard Textbook Of Electricity](https://www.bartleby.com/isbn_cover_images/9781337900348/9781337900348_smallCoverImage.jpg)
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
![Programmable Logic Controllers](https://www.bartleby.com/isbn_cover_images/9780073373843/9780073373843_smallCoverImage.gif)
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
![Fundamentals of Electric Circuits](https://www.bartleby.com/isbn_cover_images/9780078028229/9780078028229_smallCoverImage.gif)
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
![Electric Circuits. (11th Edition)](https://www.bartleby.com/isbn_cover_images/9780134746968/9780134746968_smallCoverImage.gif)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
![Engineering Electromagnetics](https://www.bartleby.com/isbn_cover_images/9780078028151/9780078028151_smallCoverImage.gif)
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,