A 3-phase generator (30 MVA, 13.8 KV, 0.15) supplies two motors (rated at 20 MVA, 12.8 KV, 20%, and 10 MVA, 12.8 KV, 20%, respectively) through a step-up transformer - transmission line - step- down transformer arrangement. The 3-phase transformers are rated at 35 MVA, 13.2 KV-A/115 KV-Y with 10 % leakage reactance. The line reactance is 80 ohms. Draw the equivalent per unit reactance diagram by selecting 30 MVA, 13.8 KV in the generator circuit. Also, calculate the current supplied by the source and the currents of each motor

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
Help me with this, I really need it
A 3-phase generator (30 MVA, 13.8 KV, 0.15) supplies two motors (rated at 20 MVA, 12.8
KV, 20%, and 10 MVA, 12.8 KV, 20%, respectively) through a step-up transformer -
transmission line - step- down transformer arrangement. The 3-phase transformers are
rated at 35 MVA, 13.2 KV-A/115 KV-Y with 10 % leakage reactance. The line reactance is 80
ohms. Draw the equivalent per unit reactance diagram by selecting 30 MVA, 13.8 KV in
the generator circuit. Also, calculate the current supplied by the source and the currents
of each motor
Transcribed Image Text:A 3-phase generator (30 MVA, 13.8 KV, 0.15) supplies two motors (rated at 20 MVA, 12.8 KV, 20%, and 10 MVA, 12.8 KV, 20%, respectively) through a step-up transformer - transmission line - step- down transformer arrangement. The 3-phase transformers are rated at 35 MVA, 13.2 KV-A/115 KV-Y with 10 % leakage reactance. The line reactance is 80 ohms. Draw the equivalent per unit reactance diagram by selecting 30 MVA, 13.8 KV in the generator circuit. Also, calculate the current supplied by the source and the currents of each motor
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 4 images

Blurred answer
Knowledge Booster
Thermistors
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,