A 2000 kVA, 6600/400 V, 3-phase transformer is connected in A-Y. The open circuit test and short circuit test was performed the following data were b) recorded: Short circuit test; H.V data: 400 V, 175 A and 17 kW. Open circuit test; L.V data: 400 V, 150 A and 15 kW Compute the following: i) The percentage of resistance drop. ii) The percentage of reactance drop. iii) The voltage regulation on full load 0.8 power factor leading.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

plz answer all

 

QUESTION 3
A 2000 kVA, 33/0.433 kV, three-phase, 50 Hz, two winding transformer has four
2.5 % taps on its primary winding and percentage impedance of (1 + j7) 2.
Assume the supply voltage remains constant.
a)
i)
Draw the two winding transformer and clearly indicate the four taps on the
primary.
Calculate the tapping that should be used to maintain 433 V, if on-load
secondary voltage reduces to 422 V.
ii)
iii)
Determine the tapping that must be used to maintain rated voltage at the
secondary on full load at 0.8 lagging power factor.
A 2000 kVA, 6600/400 V, 3-phase transformer is connected in A-Y. The
open circuit test and short circuit test was performed the following data were
recorded:
b)
Short circuit test; H.V data: 400 V, 175 A and 17 kW.
Open circuit test; L.V data: 400 V, 150 A and 15 kW
Compute the following:
i)
The percentage of resistance drop.
ii)
The percentage of reactance drop.
iii)
The voltage regulation on full load 0.8 power factor leading.
Transcribed Image Text:QUESTION 3 A 2000 kVA, 33/0.433 kV, three-phase, 50 Hz, two winding transformer has four 2.5 % taps on its primary winding and percentage impedance of (1 + j7) 2. Assume the supply voltage remains constant. a) i) Draw the two winding transformer and clearly indicate the four taps on the primary. Calculate the tapping that should be used to maintain 433 V, if on-load secondary voltage reduces to 422 V. ii) iii) Determine the tapping that must be used to maintain rated voltage at the secondary on full load at 0.8 lagging power factor. A 2000 kVA, 6600/400 V, 3-phase transformer is connected in A-Y. The open circuit test and short circuit test was performed the following data were recorded: b) Short circuit test; H.V data: 400 V, 175 A and 17 kW. Open circuit test; L.V data: 400 V, 150 A and 15 kW Compute the following: i) The percentage of resistance drop. ii) The percentage of reactance drop. iii) The voltage regulation on full load 0.8 power factor leading.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Digital Modulation Scheme (Amplitude-Shift Keying [ASK], Phase-Shift Keying [PSK], Frequency-Shift Keying [FSK])
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,