A 100KVA, 220V, star connected alternator is loaded at full-load and at 60% pf lagging. The effective AC resistance per phase is 0.014110. If the synchronous reactance is 4.5 times the effect of the armature leakage reactance wherein the later is 0.046 N per phase, find (a) the phase voltage which would be generated at the load (b) What no-load open circuit phase voltage is required to circulate full-load current at short-circuit condition with no-change made at the speed and field current? (c) What is the alternators terminal phase voltage at shorted load condition? Explain and justify your answer in one(1) sentence. Use la as the reference phasor.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
A 100KVA, 220V, star connected alternator is loaded at full-load and at 60% pf lagging.
The effective AC resistance per phase is 0.014110. If the synchronous reactance is 4.5
times the effect of the armature leakage reactance wherein the later is 0.046 n per
phase, find
(a) the phase voltage which would be generated at the load
(b) What no-load open circuit phase voltage is required to circulate full-load current at
short-circuit condition with no-change made at the speed and field current?
(c) What is the alternators terminal phase voltage at shorted load condition? Explain
and justify your answer in one(1) sentence.
Use la as the reference phasor.
Transcribed Image Text:A 100KVA, 220V, star connected alternator is loaded at full-load and at 60% pf lagging. The effective AC resistance per phase is 0.014110. If the synchronous reactance is 4.5 times the effect of the armature leakage reactance wherein the later is 0.046 n per phase, find (a) the phase voltage which would be generated at the load (b) What no-load open circuit phase voltage is required to circulate full-load current at short-circuit condition with no-change made at the speed and field current? (c) What is the alternators terminal phase voltage at shorted load condition? Explain and justify your answer in one(1) sentence. Use la as the reference phasor.
Expert Solution
steps

Step by step

Solved in 5 steps with 1 images

Blurred answer
Knowledge Booster
Synchronous Motor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,