A 100/500 V, 1 KVA, 50 Hz transformer was put through open and short-circuit tests to find its parameters. The test conditions and derived parameters are as follows: internal Open circuit test: The high voltage side terminals were open. The low voltage side was connected to 10020°, 50 Hz supply. The low voltage side current was measured as 50445º mA. Short-circuit test: The high voltage side terminals were short-circuited. The low voltage side was connected to a variable voltage supply (50 Hz). A full load current of 102-30° A was achieved when the variable voltage supply was at 840° V. The transformer was then put to operation by connecting a load of 400430° N to the high voltage side (secondary) while applying a primary voltage of 10020° V. Calculate the primary current (the current drawn from the power supply).

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

answer: 5.19 – j2.95 A 

A 100/500 V, 1 KVA, 50 Hz transformer was put through open and short-circuit tests to find its
internal parameters. The test conditions and derived parameters are as follows:
Open circuit test:
The high voltage side terminals were open.
The low voltage side was connected to 1000°, 50 Hz supply.
The low voltage side current was measured as 50445° mA.
Short-circuit test:
The high voltage side terminals were short-circuited.
The low voltage side was connected to a variable voltage supply (50 Hz).
A full load current of 102-30° A was achieved when the variable voltage supply was at 840° V.
The transformer was then put to operation by connecting a load of 400430° N to the high
voltage side (secondary) while applying a primary voltage of 10040° V.
Calculate the primary current (the current drawn from the power supply).
Transcribed Image Text:A 100/500 V, 1 KVA, 50 Hz transformer was put through open and short-circuit tests to find its internal parameters. The test conditions and derived parameters are as follows: Open circuit test: The high voltage side terminals were open. The low voltage side was connected to 1000°, 50 Hz supply. The low voltage side current was measured as 50445° mA. Short-circuit test: The high voltage side terminals were short-circuited. The low voltage side was connected to a variable voltage supply (50 Hz). A full load current of 102-30° A was achieved when the variable voltage supply was at 840° V. The transformer was then put to operation by connecting a load of 400430° N to the high voltage side (secondary) while applying a primary voltage of 10040° V. Calculate the primary current (the current drawn from the power supply).
Expert Solution
steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Methods of Wiring
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,