A 100 kVA, 380 V, 50 Hz, Y-connected synchronmous generator was tested with a rated field crent value of 3A and open circuit terminal voltage was measured as VT,oc-400 V and short circuit line current was measured as Ih,sc=220 A for this conditions. When a DC voltage of 20 V was applied to two of the terminals (between the ends of two phase coils), a current of 20 A was measured as a phase coil current. Under the given conditions, find the internal generated voltage (Ea=?), stator resistance (Ra=?) and synchronous reactance (Xs=?) values if the field current was applied with its rated value
A 100 kVA, 380 V, 50 Hz, Y-connected synchronmous generator was tested with a rated field crent value of 3A and open circuit terminal voltage was measured as VT,oc-400 V and short circuit line current was measured as Ih,sc=220 A for this conditions. When a DC voltage of 20 V was applied to two of the terminals (between the ends of two phase coils), a current of 20 A was measured as a phase coil current. Under the given conditions, find the internal generated voltage (Ea=?), stator resistance (Ra=?) and synchronous reactance (Xs=?) values if the field current was applied with its rated value
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.33P: Consider the three single-phase two-winding transformers shown in Figure 3.37. The high-voltage...
Related questions
Concept explainers
Synchronous Generator
In comparison to an asynchronous generator, it is a machine where the rotor speed is equal to the rotating magnetic field produced by the stator, i.e., mechanical speed is equal to the electrical speed, thus called synchronous, and not asynchronous.
Salient Pole Rotor
Salient pole rotor includes a large number of exposed poles mounted on a magnetic wheel. The construction of a bright pole is as shown in the image on the left. The proposed poles are made of metal laminations. The rotor winding is provided on these poles and is supported by pole shoes.
Question
A 100 kVA, 380 V, 50 Hz, Y-connected synchronmous generator was tested with a rated field crent value of 3A and open circuit terminal voltage was measured as VT,oc-400 V and short circuit line current was measured as Ih,sc=220 A for this conditions. When a DC voltage of 20 V was applied to two of the terminals (between the ends of two phase coils), a current of 20 A was measured as a phase coil current. Under the given conditions, find the internal generated voltage (Ea=?), stator resistance (Ra=?) and synchronous reactance (Xs=?) values if the field current was applied with its rated value.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 4 steps with 3 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning